Electric pulp tester conductance through various interface media.

André K Mickel1, Kimberly A D Lindquist, Sami Chogle, Jefferson J Jones, Francis Curd.   

Abstract

A conducting media is necessary when using an electric pulp tester (EPT). The objective of this study was to observe differences in conductance through various media. We hypothesized that variations in current conductance through different media exist. The pulp chamber of a freshly extracted premolar was exposed, and the cathode of a voltmeter was inserted into the pulpal tissue. The anode was coupled to the EPT handpiece. The measurement taken during dry (no interface media) EPT tip-to-tooth contact was 0 V, which served as negative control. EPT tip directly touching the cathode measured 3.9V and served as positive control. A number of media readily available in the dental office were tested. Data was analyzed using single factor ANOVA. Listerine (3.3) conducted the most voltage (p<0.5). Of nonliquids, K-Y Brand UltraGel and Crest Baking Soda &amp; Peroxide Whitening Tartar Control toothpaste recorded significantly (p<0.05) higher voltage readings (1.4 V).

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17174677     DOI: 10.1016/j.joen.2006.06.009

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  4 in total

1.  Comparison of the vitality tests used in the dental clinical practice and histological analysis of the dental pulp.

Authors:  Ana Tenyi; Lidija Nemeth; Aljaž Golež; Ksenija Cankar; Aleksandra Milutinović
Journal:  Bosn J Basic Med Sci       Date:  2022-06-01       Impact factor: 3.759

2.  Correlation between Histological Status of the Pulp and Its Response to Sensibility Tests.

Authors:  Mandana Naseri; Akbar Khayat; Sara Zamaheni; Shiva Shojaeian
Journal:  Iran Endod J       Date:  2017

3.  Pulp sensitivity changes during orthodontic treatment at different time periods: a prospective study.

Authors:  Benjamín Briseño-Marroquín; Héctor López-Murillo; Robert Kuchen; Adán Casasa-Araujo; Thomas Gerhard Wolf
Journal:  Clin Oral Investig       Date:  2020-12-07       Impact factor: 3.573

4.  Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis.

Authors:  Huachao Sui; Yangyang Lv; Mo Xiao; Liwen Zhou; Feng Qiao; Jinxin Zheng; Cuicui Sun; Jieni Fu; Yufan Chen; Yimeng Liu; Jie Zhou; Ligeng Wu
Journal:  BMC Oral Health       Date:  2021-07-10       Impact factor: 2.757

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.