Literature DB >> 17173995

Finger flexor motor control patterns during active flexion: an in vivo tendon force study.

Mina Nikanjam1, Katarzyna Kursa, Steve Lehman, Lisa Lattanza, Edward Diao, David Rempel.   

Abstract

An in vivo tendon force measurement system was used to evaluate index finger flexor motor control patterns during active finger flexion. During open carpal tunnel release surgery (N=12) the flexor digitorum profundus (FDP) and flexor digitorum superficilias (FDS) tendons were instrumented with buckle force transducers and participants performed finger flexion at two different wrist angles (0 degrees or 30 degrees ). During finger flexion, there was concurrent change of metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint angles, but the FDP and FDS tendon force changes were not concurrent. For the FDS tendon, no consistent changes in force were observed across participants at either wrist angle. For the FDP tendon, there were two force patterns. With the wrist in a neutral posture, the movement was initiated without force from the finger flexors, and further flexion (after the first 0.5s) was carried out with force from the FDP. With the wrist in a flexed posture, the motion was generally both initiated and continued using FDP force. At some wrist postures, finger flexion was initiated by passive forces which were replaced by FDP force to complete the motion.

Entities:  

Mesh:

Year:  2006        PMID: 17173995     DOI: 10.1016/j.humov.2006.09.002

Source DB:  PubMed          Journal:  Hum Mov Sci        ISSN: 0167-9457            Impact factor:   2.161


  7 in total

1.  Continuous ulnar nerve block at the forearm for early active mobilisation following flexor tendon reconstruction.

Authors:  T Watanabe; K Kamimura; M Shirahata; K Moriya
Journal:  Anaesth Rep       Date:  2022-10-05

2.  In vitro kinematics of the proximal interphalangeal joint in the finger after progressive disruption of the main supporting structures.

Authors:  Paolo Caravaggi; Benhoor Shamian; Linda Uko; Linda Chen; Eitan Melamed; John T Capo
Journal:  Hand (N Y)       Date:  2015-09

3.  Modeling of multiarticular muscles: importance of inclusion of tendon-pulley interactions in the finger.

Authors:  Sang Wook Lee; Derek G Kamper
Journal:  IEEE Trans Biomed Eng       Date:  2009-04-07       Impact factor: 4.538

Review 4.  Ergonomic evaluation of biomechanical hand function.

Authors:  Kyung-Sun Lee; Myung-Chul Jung
Journal:  Saf Health Work       Date:  2014-09-22

Review 5.  Modelling and in vivo evaluation of tendon forces and strain in dynamic rehabilitation exercises: a scoping review.

Authors:  Adrian Escriche-Escuder; Antonio I Cuesta-Vargas; Jose Casaña
Journal:  BMJ Open       Date:  2022-07-25       Impact factor: 3.006

6.  Finger joint motion generated by individual extrinsic muscles: a cadaveric study.

Authors:  Ashish D Nimbarte; Rodrigo Kaz; Zong-Ming Li
Journal:  J Orthop Surg Res       Date:  2008-07-11       Impact factor: 2.359

7.  Assessing Finger Joint Biomechanics by Applying Equal Force to Flexor Tendons In Vitro Using a Novel Simultaneous Approach.

Authors:  Tai-Hua Yang; Szu-Ching Lu; Wei-Jr Lin; Kristin Zhao; Chunfeng Zhao; Kai-Nan An; I-Ming Jou; Pei-Yuan Lee; Li-Chieh Kuo; Fong-Chin Su
Journal:  PLoS One       Date:  2016-08-11       Impact factor: 3.240

  7 in total