OBJECTIVES: To investigate whether ultrasound-guided vacuum biopsy (VB) with curative intent is suitable for the complete extirpation of selected sonographically detectable benign lesions of the breast, and to establish the limitations of the method with regard to lesion size and complications, the extent of scar formation and the prognostic value.
METHODS: One hundred and nine patients underwent hand-held, ultrasound-guided VB (8G or 11G needle) between June 2000 and September 2003. Of these, 45 (41%) women underwent ultrasound-guided extirpation of 46 lesions, and 42 women with 43 lesions were followed up clinically and sonographically for an average of 5.9 months. The complete extirpation rate, residual lesions, and patient satisfaction with the intervention were evaluated.
RESULTS: Removal of all sonographic evidence of lesions (median diameter, 13 mm) was achieved in 86% of cases (8G needle, 80%; 11G needle, 89%). 19% of the patients had suspected scar formation at the biopsy site. A palpable lesion in the breast could be removed by VB in 90% of cases. None of the patients developed infections and there were no hemorrhages requiring intervention, or damage to the skin or chest wall. A total of 95% of the patients stated that they would prefer this approach to open excision for possible future intervention.
CONCLUSIONS: VB is an ambulatory procedure associated with a low degree of pain. It has a high degree of patient acceptance and, as a minimally invasive biopsy technique for benign lesions, is a good alternative to open excision. The rate of complications is low and is similar to that observed with conventional microbiopsy.

Entities:  

Mesh:

Year:  2007        PMID: 17167817     DOI: 10.1002/uog.3840

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  10 in total

1.  A new method for the prevention of skin laceration during vacuum-assisted breast biopsy.

Authors:  Juan de D Berná-Serna; Florentina Guzmán-Aroca; Juan de D Berná-Mestre; Dolores Hernández-Gómez
Journal:  Br J Radiol       Date:  2017-02-09       Impact factor: 3.039

2.  Percutaneous ultrasound-guided vacuum-assisted excision of benign breast lesions: A learning curve to assess outcomes.

Authors:  Juan Pablo Salazar; Ignacio Miranda; Juan de Torres; María N Rus; Martin Espinosa-Bravo; Antonio Esgueva; Rafael Salvador; Isabel T Rubio
Journal:  Br J Radiol       Date:  2018-11-29       Impact factor: 3.039

3.  Minimally Invasive Breast Fibroadenoma Excision Using an Ultrasound-Guided Vacuum-Assisted Biopsy Device.

Authors:  Thomas Papathemelis; Stefanie Heim; Michael P Lux; Ines Erhardt; Anton Scharl; Sophia Scharl
Journal:  Geburtshilfe Frauenheilkd       Date:  2017-02       Impact factor: 2.915

4.  Rare Benign Entities of the Breast - Myoid Hamartoma and Capillary Hemangioma.

Authors:  F K Schäfer; J Biernath-Wuepping; C Eckmann-Scholz; B M Order; M Mathiak; F Hilpert; A Strauss; W Jonat; P J Schäfer
Journal:  Geburtshilfe Frauenheilkd       Date:  2012-05       Impact factor: 2.915

5.  The current role of vacuum assisted breast biopsy system in breast disease.

Authors:  Hai-Lin Park; Lee Su Kim
Journal:  J Breast Cancer       Date:  2011-03-31       Impact factor: 3.588

6.  Nonsurgical management of fibroadenoma and virginal breast hypertrophy.

Authors:  Sandhya Pruthi; Katie N Jones
Journal:  Semin Plast Surg       Date:  2013-02       Impact factor: 2.314

7.  Ultrasound Guided Therapeutic Excisional Vacuum Assisted Biopsy in Breast Fibroadenomas.

Authors:  Onur Buğdaycı; Handan Kaya; Erkin Arıbal
Journal:  J Breast Health       Date:  2017-04-01

8.  Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach.

Authors:  Stephen P Povoski; Rafael E Jimenez; Wenle P Wang
Journal:  World J Surg Oncol       Date:  2011-08-11       Impact factor: 2.754

9.  Vacuum-Assisted Excision, Scarless Solution for Fibroadenoma Breast-A Single-Center Experience.

Authors:  R Rupa; Suchana Kushvaha
Journal:  Indian J Radiol Imaging       Date:  2021-11-01

10.  Vacuum-assisted breast biopsy: a comparison of 11-gauge and 8-gauge needles in benign breast disease.

Authors:  Markus Hahn; Stella Okamgba; Peter Scheler; Klaus Freidel; Gerald Hoffmann; Bernhard Kraemer; Diethelm Wallwiener; Ute Krainick-Strobel
Journal:  World J Surg Oncol       Date:  2008-05-19       Impact factor: 2.754

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.