Literature DB >> 17166539

Ultrasonic measurement of anisotropy and temperature dependence of elastic parameters by a dry coupling method applied to a 6061-T6 alloy.

F Augereau1, D Laux, L Allais, M Mottot, C Caes.   

Abstract

A pulse-echo ultrasonic method is presented to measure elastic parameter variations during thermal loading with high accuracy. Using a dry coupling configuration dedicated to high temperature investigation, this technique has been applied on 6061-T6 aluminium samples up to 220 degrees C. Experimental settings are described to assess the measurement reproducibility estimated at a value of 0.2%. Consequently, the anisotropy of this aluminium between the rolling direction and two orthogonal axes has been clearly detected and also measured versus temperature. As regards the temperature dependence of these elastic parameters, these results are compared with the estimations of the Young's modulus obtained during mechanical tests in conditions of low cycle fatigue (LCF). The same linear variation versus temperature is found but with a shift of 7GPa. This difference has been classically attributed to systematic experimental error sources and to the distinction existing between dynamic and static elastic modulus.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17166539     DOI: 10.1016/j.ultras.2006.10.002

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  1 in total

1.  Investigating the thermally induced acoustoelastic effect in isotropic media with Lamb waves.

Authors:  Jacob C Dodson; Daniel J Inman
Journal:  J Acoust Soc Am       Date:  2014-11       Impact factor: 1.840

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.