Literature DB >> 17165834

Bead-assisted displacement immunoassay for staphylococcal enterotoxin B on a microchip.

Amanda J Haes1, Alex Terray, Greg E Collins.   

Abstract

A microchip-based, displacement immunoassay for the sensitive laser-induced fluorescence detection of staphylococcal enterotoxin B is presented. The glass microchip device consists of a microchannel that contains a double weir structure for supporting antibody-functionalized microbeads. After a 30-min sample preparation step, the displacement assay was performed without user intervention and produced quantitative results in an additional 20 min. Linear detection responses were observed over 6 orders of magnitude and provided detection limits down to 1 fM (28.5 fg/mL). The surprisingly low detection limits are hypothesized to arise from field-based enrichment analogous to field-amplified stacking, chromatographic effects, and limited diffusion lengths in the microbead bed. The assay was challenged with bovine serum albumin, casein, and milk sample matrixes. This system has the potential to provide highly sensitive detection capabilities for target biomolecules.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17165834     DOI: 10.1021/ac061057s

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Sandwich electrochemical immunoassay for the detection of Staphylococcal enterotoxin B based on immobilized thiolated antibodies.

Authors:  Madhu Prakash Chatrathi; Joseph Wang; Greg E Collins
Journal:  Biosens Bioelectron       Date:  2007-01-16       Impact factor: 10.618

2.  Chip-based immunoaffinity CE: application to the measurement of brain-derived neurotrophic factor in skin biopsies.

Authors:  Terry M Phillips; Edward F Wellner
Journal:  Electrophoresis       Date:  2009-07       Impact factor: 3.535

3.  Photonic crystal lab-on-a-chip for detecting staphylococcal enterotoxin B at low attomolar concentration.

Authors:  Jin-Hee Han; Hee-Joo Kim; L Sudheendra; Shirley J Gee; Bruce D Hammock; Ian M Kennedy
Journal:  Anal Chem       Date:  2013-03-07       Impact factor: 6.986

4.  Assessment of chemokine profiles in human skin biopsies by an immunoaffinity capillary electrophoresis chip.

Authors:  Heather Kalish; Terry M Phillips
Journal:  Methods       Date:  2011-12-17       Impact factor: 3.608

Review 5.  A Review of the Methods for Detection of Staphylococcus aureus Enterotoxins.

Authors:  Shijia Wu; Nuo Duan; Huajie Gu; Liling Hao; Hua Ye; Wenhui Gong; Zhouping Wang
Journal:  Toxins (Basel)       Date:  2016-06-24       Impact factor: 4.546

  5 in total