Literature DB >> 17165449

Anaerobic treatment of organic chemical wastewater using packed bed reactors.

P Mijaylova-Nacheva1, B Peña-Loera, S Cuevas-Velasco.   

Abstract

The studied organic chemical wastewater had a high COD, 20-45g/L, and low TSS, less than 200 mg/L, making anaerobic bio-filtration a suitable treatment method. The organic matter consisted of alcohols, amines, ketones and aromatic compounds, such as toluene and phenol. Granulated activated carbon (GAC) and a porous stone called tezontle, widely available in Mexico, were used as a bio-film support. Once inoculated, the mesophilic reactors with granulated activated carbon (GAC-BFs) reached stability with 80% COD removal in 40 days, while the reactors with tezontle material (tezontle-BF) required 145 days. Biodegradation of more than 95% was obtained with both support media: at organic loads less than 1.7 kg m(-3) d (-1) in tezontle-BF and with loads of up to 13.3 kg m(-3) d(-1) in GAC-BFs. The bio-filters with GAC allowed COD removal efficiency of 80% at a load as high as 26.3 kg m (-3) d(-1), while the same efficiency with tezontle was obtained at loads up to 4.45 kgm (-3d) (-1). The use of GAC as support material allows greater biodegradation rates than tezontle and it makes the bio-filters more resistant to organic increases, inhibition effects and toxicity. Methanogenic activity was inhibited at loads higher than 1.7 kg m(-3) d(-1) in bio-filters with tezontle and 22.8 kg m(-3) d(-1 ) in bio-filters with GAC. At loads lower than the previously mentioned, high methane production yield was obtained, 0.32-0.35 m(3) CH4/kg COD removed. The biomass growth rates were low in the bio-filters with both kinds of material; however, a sufficiently high biomass holdup was obtained.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17165449     DOI: 10.2166/wst.2006.803

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  1 in total

1.  Potential of ultrafiltration for organic matter removal in the polymer industry effluent based on particle size distribution analysis.

Authors:  Serdar Doğruel; Emine Ubay Çokgör; Orhan Ince; Seval Sözen; Derin Orhon
Journal:  Environ Sci Pollut Res Int       Date:  2012-05-15       Impact factor: 4.223

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.