Literature DB >> 17164599

The effectiveness of radon remediation in Irish schools.

Hugh Synnott1, Peter Anthony Colgan, Olwyn Hanley, David Fenton.   

Abstract

An advisory reference level of 200 Bq m(-3) and a statutory reference level of 400 Bq m(-3) apply to radon exposure in Irish schools. Following the results of a national survey of radon in Irish schools, several hundred classrooms were identified in which the reference levels were exceeded and a remediation program was put in place. This paper provides an initial analysis of the effectiveness of that remediation program. All remediation techniques proved successful in reducing radon concentrations. Active systems such as radon sumps and fan assisted under-floor ventilation were generally applied in rooms with radon concentrations above 400 Bq m(-3). These proved most effective with average radon reduction factors of 9 to 34 being achieved for radon sumps and 13 to 57 for fan assisted under-floor ventilation. Both of these techniques achieved maximum radon reduction factors in excess of 100. The highest average reduction factors were associated with the highest initial radon concentrations. Passive remediation systems such as wall and window vents were used to increase background ventilation in rooms with radon concentrations below 400 Bq m(-3) and achieved average radon reductions of approximately 55%. Following the installation of active remediation systems, the radon concentration in adjacent rooms, i.e., rooms in which the radon concentration was already below 200 Bq m(-3) and therefore did not require remediation, was further reduced by an average of 25%. The long-term effectiveness of a number of radon sump systems with at least three years operation showed no evidence of fan failures. This study showed an apparent increase in sump effectiveness with time as indicated by an increase in radon reduction factors during this period.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17164599     DOI: 10.1097/01.HP.0000234038.25522.98

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  3 in total

1.  Radon in Schools: A Review of Radon Testing Efforts in Canadian Schools.

Authors:  Sandy Shergill; Lindsay Forsman-Phillips; Anne-Marie Nicol
Journal:  Int J Environ Res Public Health       Date:  2021-05-20       Impact factor: 3.390

Review 2.  Radon in Schools: A Brief Review of State Laws and Regulations in the United States.

Authors:  Kelsey Gordon; Paul D Terry; Xingxing Liu; Tiffany Harris; Don Vowell; Bud Yard; Jiangang Chen
Journal:  Int J Environ Res Public Health       Date:  2018-09-30       Impact factor: 3.390

3.  Associations Between School Characteristics and Classroom Radon Concentrations in Utah's Public Schools: A Project Completed by University Environmental Health Students.

Authors:  Elizabeth A Davis; Judy Y Ou; Cheyenne Chausow; Marco A Verdeja; Eleanor Divver; James D Johnston; John D Beard
Journal:  Int J Environ Res Public Health       Date:  2020-08-12       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.