Literature DB >> 17159671

Testing of modified zeolite hemostatic dressings in a large animal model of lethal groin injury.

Naresh Ahuja1, Todd A Ostomel, Peter Rhee, Galen D Stucky, Richard Conran, Zheng Chen, Ghada A Al-Mubarak, George Velmahos, Marc Demoya, Hasan B Alam.   

Abstract

BACKGROUND: We have previously identified a granular zeolite hemostat (ZH) as an effective agent for control of severe bleeding, and it is currently being used by the US troops in the battlefield. ZH causes an exothermic reaction on application, which theoretically can be decreased by altering its chemical composition or changing its physical properties. However, the effect of these alterations on the hemostatic efficacy is unknown. We tested modified zeolites and a chitosan based dressing against controls in a swine model of battlefield injury.
METHODS: A complex groin injury was created in 60 swine (40-55 kg). This included semi-transection of the proximal thigh (level of inguinal ligament), and complete division of the femoral artery and vein. After 3 minutes, the animals were assigned to (1) no dressing (ND), (2) standard dressing (SD), (3-5) SD + chemically modified ZHs, where calcium was substituted with sodium (Na), barium (Ba), or silver (Ag), respectively, (6) SD + physically modified ZH, where "beads" were packaged in a fabric bag, (7) SD + chitosan based dressing (CD). Resuscitation was started 15 minutes after application of dressing (500 mL of 6% hetastarch over 30 minutes). Survival for 180 minutes was the primary endpoint for this study. In addition, blood loss, wound temperatures, and histologic tissue damage were recorded.
RESULTS: Mortality in the group that was treated with the application of bagged ZH was 10% versus 100% in the no dressing group and 50% in the SD group (p < 0.05 vs. ND and SD groups). The Na ZH group had a mortality rate of 43%, whereas application of Ba and Ag substituted zeolites, and CD were associated with a mortality rate of 25%. Ionic substitution of zeolite decreased the in vivo temperature peak by 5 to 10 degrees C. No histologic evidence of tissue necrosis was noted in this experiment.
CONCLUSIONS: The use of zeolite hemostat can control hemorrhage and dramatically reduce mortality from a lethal groin wound. Modifications of zeolite hemostat can decrease the exothermic reaction and attenuate tissue damage.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17159671     DOI: 10.1097/01.ta.0000240597.42420.8f

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  7 in total

Review 1.  Current use of live tissue training in trauma: a descriptive systematic review.

Authors:  Luis Teodoro da Luz; Bartolomeu Nascimento; Homer Tien; Michael J Kim; Avery B Nathens; Savvas Vlachos; Elon Glassberg
Journal:  Can J Surg       Date:  2015-06       Impact factor: 2.089

2.  Porcine liver injury model to assess tantalum-containing bioactive glass powders for hemostasis.

Authors:  Malvika Nagrath; Danielle Bince; Corwyn Rowsell; Deanna Polintan; Joao Rezende-Neto; Mark Towler
Journal:  J Mater Sci Mater Med       Date:  2022-06-07       Impact factor: 4.727

3.  The design and testing of a dual fiber textile matrix for accelerating surface hemostasis.

Authors:  Thomas H Fischer; John N Vournakis; James E Manning; Shane L McCurdy; Preston B Rich; Timothy C Nichols; Christopher M Scull; Marian G McCord; Joseph A Decorta; Peter C Johnson; Carr J Smith
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-10       Impact factor: 3.368

Review 4.  [Hemostyptics for treatment of junctional vascular injuries : Management of traumatic vascular injuries at the transition from trunk to extremities].

Authors:  D C Hinck; S Wipper; E S Debus
Journal:  Unfallchirurg       Date:  2018-07       Impact factor: 1.000

5.  Comparison of hemostatic dressings for superficial wounds using a new spectrophotometric coagulation assay.

Authors:  Julian-Dario Rembe; Julia K Böhm; Carolin Fromm-Dornieden; Nadine Schäfer; Marc Maegele; Matthias Fröhlich; Ewa K Stuermer
Journal:  J Transl Med       Date:  2015-11-30       Impact factor: 5.531

6.  A review of the application of cellulose hemostatic agent on trauma injuries.

Authors:  Hadi Khoshmohabat; Shahram Paydar; Alireza Makarem; Mohammad Yasin Karami; Niloofar Dastgheib; Seyed Ali Hossein Zahraei; Rohallah Rezaei; Golnoush Sadat Mahmoudi Nezhad
Journal:  Open Access Emerg Med       Date:  2019-08-01

7.  Adenosine diphosphate-decorated chitosan nanoparticles shorten blood clotting times, influencing the structures and varying the mechanical properties of the clots.

Authors:  Tze-Wen Chung; Pei-Yi Lin; Shoei-Shen Wang; Yen-Fung Chen
Journal:  Int J Nanomedicine       Date:  2014-03-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.