Literature DB >> 17159170

Should we reconsider all-polyethylene tibial implants in total knee replacement?

S D Muller1, D J Deehan, J P Holland, S E Outterside, L M G Kirk, P J Gregg, A W McCaskie.   

Abstract

The role of modular tibial implants in total knee replacement is not fully defined. We performed a prospective randomised controlled clinical trial using radiostereophotogrammetric analysis to compare the performance of an all-polyethylene tibia with a metal-backed cruciate-retaining condylar design, PFC-Sigma total knee replacement for up to 24 months. There were 51 patients who were randomised into two treatment groups. There were 10 subsequent withdrawals, leaving 21 all-polyethylene and 20 metal-backed tibial implants. No patient was lost to follow-up. There were no significant demographic differences between the groups. At two years one metal-backed implant showed migration > 1 mm, but no polyethylene implant reached this level. There was a significant increase in the SF-12 and Oxford knee scores after operation in both groups. In an uncomplicated primary total knee replacement the all-polyethylene PFC-Sigma tibial prosthesis showed no statistical difference in migration from that of the metal-backed counterpart. There was no difference in the clinical results as assessed by the SF-12, the Oxford knee score, alignment or range of movement at 24 months, although these assessment measures were not statistically powered in this study.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17159170     DOI: 10.1302/0301-620X.88B12.17695

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

Review 1.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

2.  Predicting range of movement after knee replacement: the importance of posterior condylar offset and tibial slope.

Authors:  Ajay Malviya; E A Lingard; D J Weir; D J Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-01-13       Impact factor: 4.342

3.  All-polyethylene tibial components are not inferior to metal-backed tibial components in long-term follow-up of knee arthroplasties.

Authors:  Mustafa Yassin; Avraham Garti; Moshe Weissbrot; Uzi Ashkenazi; Muhammed Khatib; Dror Robinson
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-05-26

Review 4.  All-polyethylene tibial components are equal to metal-backed components: systematic review and meta-regression.

Authors:  Klaas Auke Nouta; Wiebe C Verra; Bart G Pijls; Jan W Schoones; Rob G H H Nelissen
Journal:  Clin Orthop Relat Res       Date:  2012-09-13       Impact factor: 4.176

5.  All-polyethylene and metal-backed tibial components are equivalent with BMI of less than 37.5.

Authors:  Jared Toman; Richard Iorio; William L Healy
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

Review 6.  All-polyethylene versus metal-backed tibial component in total knee arthroplasty.

Authors:  Umile Giuseppe Longo; Mauro Ciuffreda; Valerio D'Andrea; Nicholas Mannering; Joel Locher; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-21       Impact factor: 4.342

7.  All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty.

Authors:  Jean Brihault; Alessandro Navacchia; Silvia Pianigiani; Luc Labey; Ronny De Corte; Valerio Pascale; Bernardo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-05-10       Impact factor: 4.342

Review 8.  Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.

Authors:  Bart G Pijls; Edward R Valstar; Klaas-Auke Nouta; Josepha Wm Plevier; Marta Fiocco; Saskia Middeldorp; Rob Ghh Nelissen
Journal:  Acta Orthop       Date:  2012-11-09       Impact factor: 3.717

9.  All-polyethylene tibial components in TKA in rheumatoid arthritis: a 25-year follow-up study.

Authors:  Klaas-Auke Nouta; Bart G Pijls; Rob G H H Nelissen
Journal:  Int Orthop       Date:  2011-09-01       Impact factor: 3.075

10.  Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty.

Authors:  Tao Cheng; Guoyou Zhang; Xianlong Zhang
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.