Literature DB >> 17159034

A newly designed glaucoma drainage implant made of poly(styrene-b-isobutylene-b-styrene): biocompatibility and function in normal rabbit eyes.

Ana C Acosta1, Edgar M Espana, Hideo Yamamoto, Stewart Davis, Leonard Pinchuk, Bruce A Weber, Marcia Orozco, Sander Dubovy, Francisco Fantes, Jean-Marie Parel.   

Abstract

OBJECTIVE: To report clinical evaluation, flow patency, and histopathological findings of a novel glaucoma drainage implant (GDI) made of poly(styrene-b-isobutylene-b-styrene) (SIBS) in rabbits.
METHODS: In 16 normal eyes, the proximal end of the SIBS GDI was inserted into the anterior chamber while the distal end was placed in the subconjunctival space. A control group underwent implantation of a similarly designed silicone GDI. Slitlamp follow-up and intraocular pressure measurements were recorded. Flow patency was evaluated by injecting 0.01% fluorescein into the anterior chamber. Immunostaining against collagen IV, macrophages, and alpha smooth muscle actin was performed.
RESULTS: Slitlamp examination suggested adequate biocompatibility. A low and diffuse bleb was observed in the SIBS group. All SIBS tubes were patent 6 months after insertion. Immunostaining demonstrated noncontinuous collagen deposition. No macrophages or myofibroblasts were visible around the SIBS tubes. In contrast, silicone induced collagen deposition and myofibroblast differentiation.
CONCLUSION: This new GDI is clinically biocompatible in the rabbit and maintained 100% patency at 6 months. A remarkable difference was the absence of myofibroblasts in the surrounding tissue in the SIBS group. CLINICAL RELEVANCE: This novel GDI made of SIBS would prevent the feared complication of hypotony and will decrease the amount of subconjunctival fibrosis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17159034     DOI: 10.1001/archopht.124.12.1742

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  21 in total

Review 1.  A review of in vivo animal studies in retinal prosthesis research.

Authors:  Dimiter R Bertschinger; Evgueny Beknazar; Manuel Simonutti; Avinoam B Safran; José A Sahel; Serge G Rosolen; Serge Picaud; Joel Salzmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-08-16       Impact factor: 3.117

2.  One-year outcomes of microshunt implantation in pseudoexfoliation glaucoma.

Authors:  Matthias Nobl; Sigrid Freissinger; Stefan Kassumeh; Siegfried Priglinger; Marc J Mackert
Journal:  PLoS One       Date:  2021-08-27       Impact factor: 3.240

3.  In vivo biocompatibility assessment of (PTFE-PVDF-PP) terpolymer-based membrane with potential application for glaucoma treatment.

Authors:  Rafał Leszczynski; Ewa Stodolak; Jarosław Wieczorek; Jolanta Orlowska-Heitzman; Teresa Gumula; Stanislaw Blazewicz
Journal:  J Mater Sci Mater Med       Date:  2010-07-23       Impact factor: 3.896

Review 4.  Modern concepts in antiglaucomatous implant surgery.

Authors:  T S Dietlein; J Jordan; C Lueke; G K Krieglstein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-08-06       Impact factor: 3.117

5.  A new manner of reporting pressure results after glaucoma surgery.

Authors:  Constantin-Dan Bordeianu; Cristina-Eugenia Ticu
Journal:  Clin Ophthalmol       Date:  2011-12-30

Review 6.  Microinvasive glaucoma surgery: a review and classification of implant-dependent procedures and techniques.

Authors:  Joanna Jabłońska; Katarzyna Lewczuk; Joanna Konopińska; Zofia Mariak; Marek Rękas
Journal:  Acta Ophthalmol       Date:  2021-05-14       Impact factor: 3.988

Review 7.  Glaucoma surgery: taking the sub-conjunctival route.

Authors:  Tarek Shaarawy
Journal:  Middle East Afr J Ophthalmol       Date:  2015 Jan-Mar

Review 8.  Ab externo implantation of the MicroShunt, a poly (styrene-block-isobutylene-block-styrene) surgical device for the treatment of primary open-angle glaucoma: a review.

Authors:  Omar Sadruddin; Leonard Pinchuk; Raymund Angeles; Paul Palmberg
Journal:  Eye Vis (Lond)       Date:  2019-11-15

Review 9.  The use of poly(styrene-block-isobutylene-block-styrene) as a microshunt to treat glaucoma.

Authors:  Leonard Pinchuk; Isabelle Riss; Juan F Batlle; Yasushi P Kato; John B Martin; Esdras Arrieta; Paul Palmberg; Richard K Parrish; Bruce A Weber; Yongmoon Kwon; Jean-Marie Parel
Journal:  Regen Biomater       Date:  2016-02-25

Review 10.  The development of a micro-shunt made from poly(styrene-block-isobutylene-block-styrene) to treat glaucoma.

Authors:  Leonard Pinchuk; Isabelle Riss; Juan F Batlle; Yasushi P Kato; John B Martin; Esdras Arrieta; Paul Palmberg; Richard K Parrish; Bruce A Weber; Yongmoon Kwon; Jean-Marie Parel
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-09-18       Impact factor: 3.368

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.