Literature DB >> 17158085

Photoacoustic monitoring of the absorption of isotonic saline solution by human mucus.

F L Dumas1, F R Marciano, L V F Oliveira, P R Barja, D Acosta-Avalos.   

Abstract

Viscosity and elasticity are the fundamental rheologic properties of respiratory mucus, and are important determinants of transportability of mucus in the mucociliary system. One technique that permits to monitor indirectly the rheologic properties of any sample is the photoacoustic technique. Using that technique, the absorption of isotonic saline solution by human mucus was monitored. The mucus was obtained from 11 volunteers, divided into two groups: five volunteers presenting pneumology symptoms (group I) and six healthy volunteers (group II). The photoacoustic signal of the mucus absorbing the saline solution was monitored as function of time, with measurements being performed each 10 min, up to 120 min. The resulting curves were fitted to sigmoidal curves to simulate the evolution on time of the photoacoustic signal. A characteristic time for the half saturation of the absorption process was obtained. For group I the time obtained was 23.3+/-5.3 min and for group II the time obtained was 55.0+/-7.7 min, both means being significantly different (Student t-test, p<0.05). This result supports the empirical practice of treating individuals presenting symptoms of airway obstruction with about 30 min of inhalations of isotonic saline solution vapor for the clearance of the airways.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17158085     DOI: 10.1016/j.medengphy.2006.10.013

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  2 in total

1.  Hypertonic saline solutions do not influence the solubility of sputum from secretor and non-secretor cystic fibrosis patients.

Authors:  Marcelo A I Barboza; Cinara C Brandão de Mattos; Ana Iara C Ferreira; Paulo R Barja; Newton Santos de Faria Junior; Luís Vicente F de Oliveira; Luiz C de Mattos
Journal:  Arch Med Sci       Date:  2011-05-17       Impact factor: 3.318

2.  Photoacoustic technique: a new method for measuring the rheologic properties of human bronchial mucus.

Authors:  Luis Vf De Oliveira; Newton S De Faria; Fernanda M Garcia Gonzaga Napoleone; Marcelo A Ingraci Barboza; Fernando S Studart Leitão Filho; Luiz C De Mattos; Claudio F Donner; Paulo R Barja
Journal:  Multidiscip Respir Med       Date:  2011-08-31
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.