Literature DB >> 17157907

An in vitro pyrogen safety test for immune-stimulating components on surfaces.

Marina Hasiwa1, Karin Kullmann, Sonja von Aulock, Christoph Klein, Thomas Hartung.   

Abstract

Due to the discovery of novel surgical techniques and new materials medical devices are increasingly used. Contact of these biomaterials with human tissue or blood commonly leads to inflammation of varying degrees, sometimes resulting in severe health problems. Possible causes are limited biocompatibility or pyrogenic contamination of the material. We adapted the recently validated in vitro pyrogen test (IPT), based on human whole blood cytokine release, to test the safety of biomaterials. Human whole blood is brought into direct contact with the surface of the test material and the release of the pro-inflammatory cytokine IL-1beta is measured. This procedure represents a human-relevant assay allowing the detection of pyrogens of different origins, e.g. Gram-negative (lipopolysaccharide, LPS) or Gram-positive (lipoteichoic acid, LTA), peptidoglycan (cell wall components of most bacteria) and fungal zymosan by direct material contact. The sensitivity of the test system allows a starting concentration of 10 pg/ml for LPS, 10 ng/ml for zymosan and 1 microg/ml for LTA and peptidoglycan from different strains. Furthermore, we have shown that the test for solid materials can be carried out with cryo-preserved blood, which results in an even lower detection limit.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17157907     DOI: 10.1016/j.biomaterials.2006.11.016

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  8 in total

1.  Assessment of lipopolysaccharide microleakage at conical implant-abutment connections.

Authors:  Sönke Harder; Elgar Susanne Quabius; Lars Ossenkop; Matthias Kern
Journal:  Clin Oral Investig       Date:  2011-12-02       Impact factor: 3.573

2.  Highly sensitive pyrogen detection on medical devices by the monocyte activation test.

Authors:  Katharina Stang; Stefan Fennrich; Stefanie Krajewski; Sandra Stoppelkamp; Iwan Anton Burgener; Hans-Peter Wendel; Marcell Post
Journal:  J Mater Sci Mater Med       Date:  2014-01-12       Impact factor: 3.896

3.  Comparison of the interleukin-1β-inducing potency of allergenic spores from higher fungi (basidiomycetes) in a cryopreserved human whole blood system.

Authors:  Félix E Rivera-Mariani; Kranthi Vysyaraju; Jesse Negherbon; Estelle Levetin; W Elliot Horner; Thomas Hartung; Patrick N Breysse
Journal:  Int Arch Allergy Immunol       Date:  2013-12-17       Impact factor: 2.749

4.  Assessment of pyrogenic contaminations with validated human whole-blood assay.

Authors:  Mardas Daneshian; Sonja von Aulock; Thomas Hartung
Journal:  Nat Protoc       Date:  2009-11-05       Impact factor: 13.491

5.  Systematic review of membrane components of gram-positive bacteria responsible as pyrogens for inducing human monocyte/macrophage cytokine release.

Authors:  Christoph Rockel; Thomas Hartung
Journal:  Front Pharmacol       Date:  2012-04-17       Impact factor: 5.810

6.  Biocompatibility of Bletilla striata Microspheres as a Novel Embolic Agent.

Authors:  ShiHua Luo; SongLin Song; ChuanSheng Zheng; Yong Wang; XiangWen Xia; Bin Liang; GanSheng Feng
Journal:  Evid Based Complement Alternat Med       Date:  2015-09-09       Impact factor: 2.629

7.  Pyrogen detection methods: comparison of bovine whole blood assay (bWBA) and monocyte activation test (MAT).

Authors:  Christian Wunderlich; Stephan Schumacher; Manfred Kietzmann
Journal:  BMC Pharmacol Toxicol       Date:  2014-09-10       Impact factor: 2.483

8.  Early Immune Response in Foreign Body Reaction Is Implant/Material Specific.

Authors:  Nicolas Söhling; Muriel Ondreka; Kerstin Kontradowitz; Tobias Reichel; Ingo Marzi; Dirk Henrich
Journal:  Materials (Basel)       Date:  2022-03-16       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.