Clinical implementation of target tracking by breathing synchronized delivery.

Dinesh Tewatia1, Tiezhi Zhang, Wolfgang Tome, Bhudatt Paliwal, Minesh Metha.   

Abstract

Target-tracking techniques can be categorized based on the mechanism of the feedback loop. In real time tracking, breathing-delivery phase correlation is provided to the treatment delivery hardware. Clinical implementation of target tracking in real time requires major hardware modifications. In breathing synchronized delivery (BSD), the patient is guided to breathe in accordance with target motion derived from four-dimensional computed tomography (4D-CT). Violations of mechanical limitations of hardware are to be avoided at the treatment planning stage. Hardware modifications are not required. In this article, using sliding window IMRT delivery as an example, we have described step-by-step the implementation of target tracking by the BSD technique: (1) A breathing guide is developed from patient's normal breathing pattern. The patient tries to reproduce this guiding cycle by following the display in the goggles; (2) 4D-CT scans are acquired at all the phases of the breathing cycle; (3) The average tumor trajectory is obtained by deformable image registration of 4D-CT datasets and is smoothed by Fourier filtering; (4) Conventional IMRT planning is performed using the images at reference phase (full exhalation phase) and a leaf sequence based on optimized fluence map is generated; (5) Assuming the patient breathes with a reproducible breathing pattern and the machine maintains a constant dose rate, the treatment process is correlated with the breathing phase; (6) The instantaneous average tumor displacement is overlaid on the dMLC position at corresponding phase; and (7) DMLC leaf speed and acceleration are evaluated to ensure treatment delivery. A custom-built mobile phantom driven by a computer-controlled stepper motor was used in the dosimetry verification. A stepper motor was programmed such that the phantom moved according to the linear component of tumor motion used in BSD treatment planning. A conventional plan was delivered on the phantom with and without motion. The BSD plan was also delivered on the phantom that moved with the prescheduled pattern and synchronized with the delivery of each beam. Film dosimetry showed underdose and overdose in the superior and inferior regions of the target, respectively, if the tumor motion is not compensated during the delivery. BSD delivery resulted in a dose distribution very similar to the planned treatments.

Entities:  

Mesh:

Year:  2006        PMID: 17153412     DOI: 10.1118/1.2359228

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method.

Authors:  Minzhi Gui; Yuanming Feng; Byongyong Yi; Anil Arvind Dhople; Cedric Yu
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  On correlated sources of uncertainty in four dimensional computed tomography data sets.

Authors:  Eric D Ehler; Wolfgang A Tome
Journal:  Technol Cancer Res Treat       Date:  2010-06

3.  Characterization of free breathing patterns with 5D lung motion model.

Authors:  Tianyu Zhao; Wei Lu; Deshan Yang; Sasa Mutic; Camille E Noel; Parag J Parikh; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

4.  Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer.

Authors:  Wei Liu; Steven E Schild; Joe Y Chang; Zhongxing Liao; Yu-Hui Chang; Zhifei Wen; Jiajian Shen; Joshua B Stoker; Xiaoning Ding; Yanle Hu; Narayan Sahoo; Michael G Herman; Carlos Vargas; Sameer Keole; William Wong; Martin Bues
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-11-10       Impact factor: 7.038

5.  Stochastic rank correlation: a robust merit function for 2D/3D registration of image data obtained at different energies.

Authors:  Wolfgang Birkfellner; Markus Stock; Michael Figl; Christelle Gendrin; Johann Hummel; Shuo Dong; Joachim Kettenbach; Dietmar Georg; Helmar Bergmann
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

6.  Performance evaluation of respiratory motion-synchronized dynamic IMRT delivery.

Authors:  S A Yoganathan; K J Maria Das; Arpita Agarwal; Shaleen Kumar
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

7.  Combination effects of tissue heterogeneity and geometric targeting error in stereotactic body radiotherapy for lung cancer using CyberKnife.

Authors:  Ki Mun Kang; Bae Kwon Jeong; Hoon-Sik Choi; Seung Hoon Yoo; Ui-Jung Hwang; Young Kyung Lim; Hojin Jeong
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

8.  Advances in radiation therapy dosimetry.

Authors:  Bhudatt Paliwal; Dinesh Tewatia
Journal:  J Med Phys       Date:  2009-07

Review 9.  Magnitude, Impact, and Management of Respiration-induced Target Motion in Radiotherapy Treatment: A Comprehensive Review.

Authors:  S A Yoganathan; K J Maria Das; Arpita Agarwal; Shaleen Kumar
Journal:  J Med Phys       Date:  2017 Jul-Sep
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.