Optimization of HDR brachytherapy dose distributions using linear programming with penalty costs.

Ron Alterovitz1, Etienne Lessard, Jean Pouliot, I-Chow Joe Hsu, James F O'Brien, Ken Goldberg.   

Abstract

Prostate cancer is increasingly treated with high-dose-rate (HDR) brachytherapy, a type of radiotherapy in which a radioactive source is guided through catheters temporarily implanted in the prostate. Clinicians must set dwell times for the source inside the catheters so the resulting dose distribution minimizes deviation from dose prescriptions that conform to patient-specific anatomy. The primary contribution of this paper is to take the well-established dwell times optimization problem defined by Inverse Planning by Simulated Annealing (IPSA) developed at UCSF and exactly formulate it as a linear programming (LP) problem. Because LP problems can be solved exactly and deterministically, this formulation provides strong performance guarantees: one can rapidly find the dwell times solution that globally minimizes IPSA's objective function for any patient case and clinical criteria parameters. For a sample of 20 prostates with volume ranging from 23 to 103 cc, the new LP method optimized dwell times in less than 15 s per case on a standard PC. The dwell times solutions currently being obtained clinically using simulated annealing (SA), a probabilistic method, were quantitatively compared to the mathematically optimal solutions obtained using the LP method. The LP method resulted in significantly improved objective function values compared to SA (P = 1.54 x 10(-7)), but none of the dosimetric indices indicated a statistically significant difference (P < 0.01). The results indicate that solutions generated by the current version of IPSA are clinically equivalent to the mathematically optimal solutions.

Entities:  

Mesh:

Year:  2006        PMID: 17153381     DOI: 10.1118/1.2349685

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Volume and landmark analysis: comparison of MRI measurements obtained with an endorectal coil and with a phased-array coil.

Authors:  Y Mazaheri; A A Afaq; S I Jung; D A Goldman; L Wang; H Aslan; M J Zelefsky; O Akin; H Hricak
Journal:  Clin Radiol       Date:  2014-12-29       Impact factor: 2.350

2.  Incorporating Treatment Time into Butterfly Optimization to Reduce Total Treatment Time for Vaginal Cylinder Brachytherapy.

Authors:  Xingen Wu; Ivan A Brezovich; Sui Shen; Elizabeth Covington; Dennis Stanley; Richard Popple
Journal:  Cureus       Date:  2022-04-06

3.  Dosimetric analysis and comparison of IMRT and HDR brachytherapy in treatment of localized prostate cancer.

Authors:  V Murali; P G G Kurup; P Mahadev; S Mahalakshmi
Journal:  J Med Phys       Date:  2010-04

4.  Radiobiological evaluation of the influence of dwell time modulation restriction in HIPO optimized HDR prostate brachytherapy implants.

Authors:  Panayiotis Mavroidis; Zaira Katsilieri; Vasiliki Kefala; Natasa Milickovic; Nikos Papanikolaou; Andreas Karabis; Nikolaos Zamboglou; Dimos Baltas
Journal:  J Contemp Brachytherapy       Date:  2010-10-13

5.  Role of step size and max dwell time in anatomy based inverse optimization for prostate implants.

Authors:  Arjunan Manikandan; Biplab Sarkar; Vivek Thirupathur Rajendran; Paul R King; N V Madhusudhana Sresty; Ragavendra Holla; Sachin Kotur; Sujatha Nadendla
Journal:  J Med Phys       Date:  2013-07

6.  Artificial intelligence can overcome challenges in brachytherapy treatment planning.

Authors:  Xun Jia; J Adam M Cunha; Yi Rong
Journal:  J Appl Clin Med Phys       Date:  2022-01       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.