Literature DB >> 17152427

Exposure of the thyroid to radiation during routine orthopaedic procedures.

Kailash L Devalia1, Viju K Peter, Mansoor A Madanur, Ian J Braithwaite.   

Abstract

The availability and usage of portable image intensifiers has revolutionised routine orthopaedic practice. Extensive use of fluoroscopy however may result into significant radiation exposure to operating staff. An accumulated dose of 65 microSv per procedure over long exposure has been reported to increase the risk of thyroid cancer. The present prospective study aimed at measuring the scattered dose to the thyroid using an Unfors EDD dosimeter during DHS/IMHS for fractures of the neck of the femur and IM nailing for long bone fractures. In 32 procedures, the dose of 65 microSv was exceeded 13 times; 8 times during DHS/IMHS and 5 times during IMN. The average thyroid dose was 142 microSv during IMN and 55 microSv during DHS. Only 9 of the total 223 (4%) theatre personnel were using a thyroid shield in spite of its availability. These results suggest that the thyroid is frequently exposed to potentially harmful radiation during these procedures. Strict inclusion of a thyroid shield as a part of routine radiation protection is recommended.

Entities:  

Mesh:

Year:  2006        PMID: 17152427

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  6 in total

1.  [X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room].

Authors:  K Dresing
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

2.  Level of knowledge on radiation exposure and compliance to wearing protective equipment: where do endourologists stand? An ESUT/EULIS survey.

Authors:  Lazaros Tzelves; Bhaskar Somani; Thomas Knoll; Guido Kamphuis; Kemal Sarica; C Seitz; E Liatsikos; Andreas Skolarikos
Journal:  World J Urol       Date:  2019-05-15       Impact factor: 4.226

3.  Current attitudes of Turkish anesthesiologists to radiation exposure.

Authors:  Adnan Tüfek; Orhan Tokgöz; Ilker Öngüç Aycan; Feyzi Çelik; Abdurrahman Gümüş
Journal:  J Anesth       Date:  2013-05-08       Impact factor: 2.078

4.  Is It Safe to Use a Lead Screen During Hip Arthroscopy?

Authors:  Alexander Rahill; Leah Biffin; Camdon Fary; Alasdair G Sutherland; Phong Tran
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-02-03

Review 5.  Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management.

Authors:  Bo Kyung Cheon; Cho Long Kim; Ka Ram Kim; Min Hye Kang; Jeong Ae Lim; Nam Sik Woo; Ka Young Rhee; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2018-10-01

6.  FLUOROSCOPY DURATION IN ORTHOPEDIC SURGERY.

Authors:  Joao Caron La Salvia; Pablo Reis de Moraes; Tiago Yossef Ammar; Carlos Roberto Schwartsmann
Journal:  Rev Bras Ortop       Date:  2015-12-06