Literature DB >> 17151066

Interbreath-hold reproducibility of lung tumour position and reduction of the internal target volume using a voluntary breath-hold method with spirometer during stereotactic radiotherapy for lung tumours.

T Kimura1, Y Murakami, M Kenjo, Y Kaneyasu, K Wadasaki, K Ito, M Ohkawa.   

Abstract

The purpose of this study was to evaluate the interbreath-hold reproducibility of the tumour (gross tumour volume, GTV) position and relative reduction of the internal target volume (ITV) using a voluntary breath-hold method with a spirometer in a clinical setting of stereotactic radiotherapy (SRT) for lung tumours 11 patients with 14 lung tumours were enrolled in this study. CT scans were performed once at the free breathing phase and five times at the breath holding phase before the first treatment day. Patients held their breath at the end-expiration phase under spirometer-based monitoring. All GTVs were delineated by a physician and the GTV centroid was calculated automatically. To evaluate the interbreath-hold reproducibility of the tumour position, we measured the distance of three dimensions (craniocaudal, CC; left-right, LR; anteroposterior, AP) and vectors between the GTV centroid and bony landmark. The reproducibility was defined as the average of the differences between the GTV centroid and bony landmark from the second to fifth CT scans with regard to that from the first CT scans. We also evaluated the relative reduction of ITV between the free breathing and breath-holding phase. The interbreath-hold reproducibility of the tumour position was 1.3+/-1.3 mm, 1.4+/-1.8 mm, 2.1+/-1.6 mm and 3.3+/-2.2 mm in CC, LR and AP directions and vectors, respectively. ITV at the breath-holding phase was significantly smaller than that at the free breathing phase (P<0.01). In conclusion, the voluntary breath-hold method with a spirometer is feasible, with relatively good reproducibility of the tumour position for SRT in the clinical setting.

Entities:  

Mesh:

Year:  2006        PMID: 17151066     DOI: 10.1259/bjr/31008031

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

1.  Intrafraction target shift comparison using two breath-hold systems in lung stereotactic body radiotherapy.

Authors:  Alejandro Prado; Daniel Zucca; Miguel Ángel De la Casa; Jaime Martí; Leyre Alonso; Paz García de Acilu; Juan García; Ovidio Hernando; Pedro Fernández-Letón; Carmen Rubio
Journal:  Phys Imaging Radiat Oncol       Date:  2022-04-29

2.  Quantifying the reduction of respiratory motion by mechanical ventilation with MRI for radiotherapy.

Authors:  Z van Kesteren; J K Veldman; M J Parkes; M F Stevens; P Balasupramaniam; J G van den Aardweg; G van Tienhoven; A Bel; I W E M van Dijk
Journal:  Radiat Oncol       Date:  2022-05-21       Impact factor: 4.309

Review 3.  Image-guided radiotherapy and motion management in lung cancer.

Authors:  S S Korreman
Journal:  Br J Radiol       Date:  2015-05-08       Impact factor: 3.039

4.  Geometric Reproducibility of Fiducial Markers and Efficacy of a Patient-Specific Margin Design Using Deep Inspiration Breath Hold for Stereotactic Body Radiation Therapy for Pancreatic Cancer.

Authors:  Sarah Han-Oh; Colin Hill; Ken Kang-Hsin Wang; Kai Ding; Jean L Wright; Sara Alcorn; Jeffrey Meyer; Joseph Herman; Amol Narang
Journal:  Adv Radiat Oncol       Date:  2021-01-22

5.  Deep inspiration breath-hold technique guided by an opto- electronic system for extracranial stereotactic treatments.

Authors:  Cristina Garibaldi; Gianpiero Catalano; Guido Baroni; Barbara Tagaste; Marco Riboldi; Maria Francesca Spadea; Mario Ciocca; Raffaella Cambria; Flavia Serafini; Roberto Orecchia
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

6.  Impact of breath-hold level on positional error aligned by stent/Lipiodol in Hepatobiliary radiotherapy with breath-hold respiratory control.

Authors:  Tzu-Jie Huang; Yun Tien; Jian-Kuen Wu; Wen-Tao Huang; Jason Chia-Hsien Cheng
Journal:  BMC Cancer       Date:  2020-07-01       Impact factor: 4.430

Review 7.  Heart Sparing Radiotherapy Techniques in Breast Cancer: A Focus on Deep Inspiration Breath Hold.

Authors:  Hayley B Stowe; Neal D Andruska; Francisco Reynoso; Maria Thomas; Carmen Bergom
Journal:  Breast Cancer (Dove Med Press)       Date:  2022-07-20

8.  A respiratory compensating system: design and performance evaluation.

Authors:  Ho-Chiao Chuang; Ding-Yang Huang; Der-Chi Tien; Ren-Hong Wu; Chung-Hsien Hsu
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.