Complications associated with the Angio-Seal arterial puncture closing device: intra-arterial deployment and occlusion by dissected plaque.

Einar Dregelid1, Guttorm Jensen, Alireza Daryapeyma.   

Abstract

The Angio-Seal arterial closure device is widely used to prevent bleeding and facilitate early ambulation after arterial puncture. We had referred to us three female patients in whom this device had been used; its sponge had been unintentionally deployed in the arterial lumen. In a fourth female patient, a dissected plaque underneath the device occluded the femoral artery. Severe lower extremity ischemia occurred in each case. One intraluminal sponge was detected only after 20 days, when the patient had developed severe symptoms due to microembolization; in another patient, ischemia occurred 9 days after intraluminal deployment. In two, or possibly three, of the cases, the superficial femoral artery had been punctured. The device should not be used when the superficial femoral artery has been punctured, in which case complications are more likely to occur. Lower limb ischemia within several months after deployment of these devices should be investigated with duplex ultrasound scanning to examine the possibility that the ischemia may be caused by the device or by device-related thrombus. It is important to register the use of such devices in the procedural reports to make it possible to link their use to eventual later ischemic events.

Entities:  

Mesh:

Year:  2006        PMID: 17145443     DOI: 10.1016/j.jvs.2006.07.034

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  6 in total

1.  Surgical treatment of complications associated with the angio-seal vascular closure device: report of three cases.

Authors:  Yasuyuki Bito; Masayuki Sakaki; Kazushige Inoue; Yoshiteru Yoshioka; Hiroki Mizoguchi
Journal:  Ann Vasc Dis       Date:  2010-09-10

2.  Late onset iatrogenic limb ischaemia after deployment of an Angio-Seal vascular closure device.

Authors:  Rama K Krishna; Nisharahmed Kherada; Nirat Beohar
Journal:  BMJ Case Rep       Date:  2015-04-26

3.  A foot ulcer caused by the use of an angio-seal arterial closure device after percutaneous transluminal angioplasty: a case report.

Authors:  Shingo Chihara; Hideki Matsuo; Katsuaki Takagi; Shoichirou Arai; Minoru Morimatsu
Journal:  Ann Vasc Dis       Date:  2012-01-31

4.  Fluoroscopic guided fogarty embolectomy for an angio-seal embolism in the popliteal artery.

Authors:  Doran Hong; Seung Hwa Lee; Hwan Hoon Chung; Bo Kyoung Seo; Sang Hoon Cha; Kee Yeol Lee; Jeong Cheon Ahn
Journal:  Korean J Radiol       Date:  2013-07-17       Impact factor: 3.500

5.  Iatrogenic claudication from a vascular closure device after cardiac catheterization.

Authors:  Luke Hermann; Evelyn Chow; W Lane Duvall
Journal:  West J Emerg Med       Date:  2010-12

6.  Successful Retrieval of an Embolized Vascular Closure Device (Angio-Seal®) After Peripheral Angioplasty.

Authors:  Philipp Jud; Rupert Portugaller; Dennis Bohlsen; Thomas Gary; Marianne Brodmann; Gerald Hackl; Franz Hafner
Journal:  Cardiovasc Intervent Radiol       Date:  2017-01-18       Impact factor: 2.740

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.