Literature DB >> 17145418

The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation device.

Roman A Litwinski1, Carlos E Donayre, Sheryl L Chow, Tae K Song, George Kopchok, Irwin Walot, Rodney A White.   

Abstract

OBJECTIVE: Endovascular repair of abdominal aortic aneurysm (AAA) is complicated by the potential for stent graft migration over time. Factors including the type of fixation, initial proximal fixation length, and dilation and elongation of the infrarenal aortic neck may contribute to device migration. We sought to determine when device migration is a real phenomenon with actual device movement that compromises aneurysm exclusion.
METHODS: Computed tomographic (CT) scans and computer reconstructions of all patients undergoing endovascular AAA repair with a passive fixation device at our institution from June 1996 to October 2004 were retrospectively reviewed. The distance from the distal renal artery to the proximal end of the stent graft at the time of initial deployment was determined for each patient. Migration was defined as a distance increase greater than 5 mm in the follow-up period; proximal fixation length, aortic neck enlargement and elongation, and neck angle were then measured. Data were further analyzed with respect to AAA growth, development of endoleak, AAA rupture, and the need for reintervention.
RESULTS: A total of 308 patients with endovascular AAA repairs using a passive fixation device had complete postoperative imaging data sets; 48 patients (15.6%) with stent graft migration of 5 mm or more were identified, and 25 (8.1%) of these had a migration of 10 mm or more. Seventeen (35.4%) of 48 migration patients had a total loss of the proximal seal zone (loss patients); their average migration distance was 17.7 +/- 12.0 mm, with a mean neck shortening of 13.6 +/- 14.2 mm, and the average proximal fixation length loss was 14.0 +/- 7.6 mm. Those 31 patients with an intact proximal seal zone (nonloss patients) showed an average migration of 9.4 +/- 3.7 mm, with a mean neck lengthening of 9.6 +/- 8.4 mm and an average proximal fixation length change of 0.7 +/- 8.0 mm. Univariate analysis demonstrated significant differences between the loss and nonloss patients in follow-up duration (65.9 +/- 20.4 months vs 45.9 +/- 26.4 months; P = .01), neck dilatation at the distal renal artery (4.6 +/- 4.5 mm vs 1.8 +/- 1.9 mm; P = .026), stent graft migration distance (17.7 +/- 12.0 mm vs 9.4 +/- 3.7 mm; P = .001), change in aortic neck length (-13.6 +/- 14.2 mm vs 9.6 +/- 8.4 mm; P < .0001), change in proximal fixation length (-14.0 +/- 7.6 mm vs 0.7 +/- 8.0 mm; P < .0001), change in AAA size (1.8 +/- 7.1 mm vs -3.6 +/- 9.7 mm; P = .033), and use of a stiff body stent graft (47.1% vs 19.4%; P = .043). However, only change in aortic neck length was statistically significant on multivariate analysis (odds ratio, 0.75; 95% confidence interval, 0.591-0.961; P = .022). There were no differences between the loss and nonloss patients in time to migration discovery, initial AAA size, initial aortic neck diameter or length, initial device oversizing, initial neck angle, neck angle increase, type II endoleak, or AAA rupture. Eight of the 17 loss patients have been treated with proximal aortic cuffs; the remainder have refused reintervention, died of unrelated causes, or elected to have open repair.
CONCLUSIONS: Postoperative elongation of the infrarenal aortic neck may create the radiographic perception of migration without necessarily causing a loss of proximal stent graft fixation. Patients with a total loss of the proximal seal zone actually have infrarenal aortic neck shortening, with a degree of neck dilatation beyond initial device oversizing that may compromise proximal fixation length. Conversely, those with an intact proximal seal zone demonstrate aortic neck elongation equivalent to migration, with no loss of proximal fixation length; these patients have a benign natural history without intervention. Thus, aortic neck dilatation beyond oversizing, aortic neck shortening, and loss of proximal fixation length are more clinically relevant predictors of proximal stent graft failure than simple migration distance.

Entities:  

Mesh:

Year:  2006        PMID: 17145418     DOI: 10.1016/j.jvs.2006.08.028

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  11 in total

1.  Fate of Aneurysmal Common Iliac Artery Landing Zones Used for Endovascular Aneurysm Repair.

Authors:  Claire L Griffin; Salvatore T Scali; Robert J Feezor; Catherine K Chang; Kristina A Giles; Javairiah Fatima; Thomas S Huber; Adam W Beck
Journal:  J Endovasc Ther       Date:  2015-08-19       Impact factor: 3.487

2.  Midterm results of endovascular abdominal aortic aneurysm repair: comparison of instruction-for-use (IFU) cases and non-IFU cases.

Authors:  Motoki Nakai; Morio Sato; Hirotatsu Sato; Hinako Sakaguchi; Fumihiro Tanaka; Akira Ikoma; Hiroki Sanda; Kouhei Nakata; Hiroki Minamiguchi; Nobuyuki Kawai; Tetsuo Sonomura; Yoshiharu Nishimura; Yoshitaka Okamura
Journal:  Jpn J Radiol       Date:  2013-06-13       Impact factor: 2.374

3.  A randomized, placebo-controlled trial of doxycycline after endoluminal aneurysm repair.

Authors:  Amy E Hackmann; Brian G Rubin; Luis A Sanchez; Patrick A Geraghty; Robert W Thompson; John A Curci
Journal:  J Vasc Surg       Date:  2008-07-15       Impact factor: 4.268

4.  Associations of cardiovascular disease risk factors and calcified atherosclerosis with aortoiliac bifurcation position: the MultiEthnic Study of Atherosclerosis.

Authors:  Nketi I Forbang; Joachim H Ix; Matthew A Allison; Michael H Criqui
Journal:  Angiology       Date:  2013-12-26       Impact factor: 3.619

5.  Multi-detector CT angiographic imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair (EVAR).

Authors:  Roberto Iezzi; M Santoro; R Dattesi; F Pirro; M Nestola; F Spigonardo; A R Cotroneo; L Bonomo
Journal:  Insights Imaging       Date:  2012-06-12

6.  Changes in suprarenal and infrarenal aortic angles after endovascular aneurysm repair.

Authors:  Ho Kyun Lee; Sang Young Chung; Jea Kyu Kim; Sung Hee Yoo; Soo Jin Na Choi
Journal:  Ann Surg Treat Res       Date:  2014-09-25       Impact factor: 1.859

Review 7.  Proximal Aortic Neck Progression: Before and After Abdominal Aortic Aneurysm Treatment.

Authors:  Konstantinos A Filis; George Galyfos; Fragiska Sigala; Konstantinos Tsioufis; Ioannis Tsagos; Georgios Karantzikos; Christos Bakoyiannis; George Zografos
Journal:  Front Surg       Date:  2017-05-04

8.  Prosthetic Graft Dilation at the Aortic Arch in the Era of Hybrid Aortic Surgery.

Authors:  Daijiro Hori; Sho Kusadokoro; Toshikazu Shimizu; Naoyuki Kimura; Atsushi Yamaguchi
Journal:  Ann Vasc Dis       Date:  2020-06-25

9.  Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair.

Authors:  Maaike A Koenrades; Marianne R F Bosscher; Jouke T Ubbink; Cornelis H Slump; Robert H Geelkerken
Journal:  J Endovasc Ther       Date:  2019-12       Impact factor: 3.487

10.  A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts.

Authors:  Andrzej Polanczyk; Marek Podyma; Lukasz Trebinski; Jaroslaw Chrzastek; Ireneusz Zbicinski; Ludomir Stefanczyk
Journal:  PLoS One       Date:  2016-04-13       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.