Literature DB >> 17144318

Secondary wastewater polishing with ultrafiltration membranes for unrestricted reuse: fouling and flushing modeling.

Leonid Gillerman1, Amos Bick, Nisan Buriakovsky, Gideon Oron.   

Abstract

The effects of operating parameters such astransmembrane pressure, retentate, and recirculation volumetric flow rates on the productivity of an ultrafiltration membrane were studied using field data and development of a management model. Correlation equations for predicting the volumetric permeate flow rates were derived from general membrane blocking laws and experimental data. The experimental data were obtained from a pilot study carried out in the Arad wastewater treatment system (a pilot plant operating in feed and bleed operation mode) located several kilometers west of the City of Arad, Israel. Correlation predictions were confirmed with the independent experimental results. The results enabled us to develop a mathematical expression accurately describing the decline in flux due to fouling.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17144318     DOI: 10.1021/es061235z

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  1 in total

1.  Inland treatment of the brine generated from reverse osmosis advanced membrane wastewater treatment plant using epuvalisation system.

Authors:  Mohannad Qurie; Jehad Abbadi; Laura Scrano; Gennaro Mecca; Sabino A Bufo; Mustafa Khamis; Rafik Karaman
Journal:  Int J Mol Sci       Date:  2013-07-03       Impact factor: 5.923