Detection of endoleaks after endovascular aneurysm repair with use of technetium-99m sulfur colloid and (99m)Tc-labeled red blood cell scans.

S William Stavropoulos1, Maxim Itkin, Paras Lakhani, Jeffrey P Carpenter, Ronald M Fairman, Abass Alavi.   

Abstract

PURPOSE: This study was performed to determine whether endoleaks could be detected after endovascular aneurysm repair (EVAR) with use of technetium-99m sulfur colloid and (99m)Tc-labeled red blood cell (RBC) nuclear medicine scans.
MATERIALS AND METHODS: There were 13 patients enrolled in this study: nine with endoleaks seen on computed tomographic (CT) angiography and four with no endoleak on CT angiography. All patients underwent regularly scheduled surveillance CT angiography examination after EVAR to evaluate for endoleak. Endoleak detection was then attempted in each patient with two nuclear medicine scans: a (99m)Tc sulfur colloid scan and a (99m)Tc-labeled RBC scan. Flow images (5 seconds per frame) were obtained for 1 minute after intravenous administration of 555 MBq (15 mCi) (99m)Tc sulfur colloid. Sequential dynamic images were then obtained every minute for 30 minutes. Next, a (99m)Tc-labeled RBC study was performed after the intravenous administration of 370-1,073 MBq (10-29 mCi) in vitro labeled (99m)Tc RBCs. Flow images were obtained, followed by sequential dynamic images obtained every minute for 30 minutes. Single photon emission CT images of the abdomen were then acquired. The nuclear medicine scans were evaluated for the presence or absence of endoleak independent of the CT angiography findings.
RESULTS: Of the nine patients with endoleaks on CT angiography, seven (78%) had them detected by nuclear medicine examinations. Two of the nine endoleaks seen on CT angiography (22%) were not seen on either scintigraphic examination. All patients with no endoleak on CT angiography had their nuclear medicine scans correctly interpreted as showing no endoleak present (n = 4; 100%). No complications occurred as a result of the nuclear medicine scans.
CONCLUSIONS: Endoleaks can be detected with (99m)Tc sulfur colloid and (99m)Tc-labeled RBC nuclear medicine scans. This initial work suggests that the sensitivities of these scintigraphic scanning methods for endoleak detection are lower than that of CT angiography.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17142703     DOI: 10.1097/01.RVI.0000241892.81074.1A

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  6 in total

Review 1.  Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management.

Authors:  Dania Daye; T Gregory Walker
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

Review 2.  Imaging of Abdominal Aortic Aneurysm: the present and the future.

Authors:  Hao Hong; Yunan Yang; Bo Liu; Weibo Cai
Journal:  Curr Vasc Pharmacol       Date:  2010-11       Impact factor: 2.719

3.  Imaging Surveillance following Endovascular Aneurysm Repair.

Authors:  Anand Shah; S William Stavropoulos
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

4.  Changes in inflammatory, coagulopathic, and fibrinolytic responses after endovascular repair of an abdominal aortic aneurysm: relationship between fibrinogen degradation product levels and endoleaks.

Authors:  Akira Ikoma; Motoki Nakai; Morio Sato; Hirotatsu Sato; Hinako Takeuchi; Fumihiro Tanaka; Hiroki Sanda; Kouhei Nakata; Hiroki Minamiguchi; Tetsuo Sonomura; Yoshiharu Nishimura; Yoshitaka Okamura
Journal:  Jpn J Radiol       Date:  2014-04-18       Impact factor: 2.374

Review 5.  Diagnostic imaging methods applied in long-term surveillance after EVAR. Will computed tomography angiography be replaced by other methods?

Authors:  Karolina Stefaniak; Michal Stanisic; Marcin Gabriel; Grzegorz Oszkinis
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-02-11       Impact factor: 1.426

Review 6.  Imaging modalities for endoleak surveillance.

Authors:  Aman Berry Williams; Zoheb Berry Williams
Journal:  J Med Radiat Sci       Date:  2021-06-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.