Literature DB >> 17142525

A novel imaging technique to measure capillary-refill time: improving diagnostic accuracy for dehydration in young children with gastroenteritis.

Itai Shavit1, Rollin Brant, Cheri Nijssen-Jordan, Roger Galbraith, David W Johnson.   

Abstract

BACKGROUND: Assessment of dehydration in young children currently depends on clinical judgment, which is relatively inaccurate. By using digital videography, we developed a way to assess capillary-refill time more objectively.
OBJECTIVE: Our goal was to determine whether digitally measured capillary-refill time assesses the presence of significant dehydration (> or = 5%) in young children with gastroenteritis more accurately than conventional capillary refill and overall clinical assessment.
METHODS: We prospectively enrolled children with gastroenteritis, 1 month to 5 years of age, who were evaluated in a tertiary-care pediatric emergency department and judged by a triage nurse to be at least mildly dehydrated. Before any treatment, we measured the weight and digitally measured capillary-refill time of these children. Pediatric emergency physicians determined capillary-refill time by using conventional methods and degree of dehydration by overall clinical assessment by using a 7-point Likert scale. Postillness weight gain was used to estimate fluid deficit; beginning 48 hours after assessment, children were reweighed every 24 hours until 2 sequential weights differed by no more than 2%. We compared the accuracy of digitally measured capillary-refill time with conventional capillary refill and overall clinical assessment by determining sensitivities, specificities, likelihood ratios, and area under the receiver operator characteristic curves.
RESULTS: A total of 83 patients were enrolled and had complete follow-up; 13 of these patients had significant dehydration (> or = 5% of body weight). The area under the receiver operator characteristic curves for digitally measured capillary-refill time and overall clinical assessment relative to fluid deficit (< 5% vs > or = 5%) were 0.99 and 0.88, respectively. Positive likelihood ratios were 11.7 for digitally measured capillary-refill time, 4.5 for conventional capillary refill, and 4.1 for overall clinical assessment.
CONCLUSIONS: Results of this prospective cohort study suggest that digitally measured capillary-refill time more accurately predicts significant dehydration (> or = 5%) in young children with gastroenteritis than overall clinical assessment.

Entities:  

Mesh:

Year:  2006        PMID: 17142525     DOI: 10.1542/peds.2006-1108

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  9 in total

Review 1.  Acute Infectious Gastroenteritis in Infancy and Childhood.

Authors:  Carsten Posovszky; Stephan Buderus; Martin Classen; Burkhard Lawrenz; Klaus-Michael Keller; Sibylle Koletzko
Journal:  Dtsch Arztebl Int       Date:  2020-09-11       Impact factor: 5.594

2.  Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb.

Authors:  Joakim Henricson; Rani Toll John; Chris D Anderson; Daniel Björk Wilhelms
Journal:  J Vis Exp       Date:  2017-12-02       Impact factor: 1.355

3.  Diagnostic accuracy of clinical dehydration scales in children.

Authors:  Anna Falszewska; Piotr Dziechciarz; Hania Szajewska
Journal:  Eur J Pediatr       Date:  2017-06-01       Impact factor: 3.183

4.  Guidelines on acute gastroenteritis in children: a critical appraisal of their quality and applicability in primary care.

Authors:  José van den Berg; Marjolein Y Berger
Journal:  BMC Fam Pract       Date:  2011-12-02       Impact factor: 2.497

Review 5.  The Diagnostic Value of Capillary Refill Time for Detecting Serious Illness in Children: A Systematic Review and Meta-Analysis.

Authors:  Susannah Fleming; Peter Gill; Caroline Jones; James A Taylor; Ann Van den Bruel; Carl Heneghan; Nia Roberts; Matthew Thompson
Journal:  PLoS One       Date:  2015-09-16       Impact factor: 3.240

6.  Lack of agreement between different observers and methods in the measurement of capillary refill time in healthy volunteers: an observational study.

Authors:  Emilio Daniel Valenzuela Espinoza; Sebastián Welsh; Arnaldo Dubin
Journal:  Rev Bras Ter Intensiva       Date:  2014 Jul-Sep

Review 7.  Advances in the Approaches Using Peripheral Perfusion for Monitoring Hemodynamic Status.

Authors:  Julianne M Falotico; Koichiro Shinozaki; Kota Saeki; Lance B Becker
Journal:  Front Med (Lausanne)       Date:  2020-12-07

8.  Clinicians' gut feeling about serious infections in children: observational study.

Authors:  Ann Van den Bruel; Matthew Thompson; Frank Buntinx; David Mant
Journal:  BMJ       Date:  2012-09-25

9.  An automated quasi-continuous capillary refill timing device.

Authors:  L L Blaxter; D E Morris; J A Crowe; C Henry; S Hill; D Sharkey; H Vyas; B R Hayes-Gill
Journal:  Physiol Meas       Date:  2015-12-07       Impact factor: 2.833

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.