Literature DB >> 17141496

Evaluation of different strategies for the development of amperometric biosensors for L-lactate.

Beatriz Prieto-Simón1, Esteve Fàbregas, Alan Hart.   

Abstract

Two strategies were investigated for the development of lactate biosensors based on sol-gel matrixes and polysulfone composite films, both containing L-lactate dehydrogenase (LDH). Firstly, reagentless disposable screen-printed electrodes (SPE's) with Meldola's Blue (MB) and the cofactor NAD(+) inside a sol-gel matrix were prepared. These showed relatively low sensitivities (260 microA/M). Secondly, mediator-modified-polysulfone-graphite composite films deposited over both cylindrical epoxy-graphite and SPE's. These electrodes showed enhanced performance characteristics: improved sensitivity (80 mA/M), detection limit (0.87 microM) and reproducibility (2%). Reagentless electrodes, incorporating NAD(+) in the polysulfone film, had a decreased sensitivity, although better than that achieved by the sol-gel electrodes. While sol-gel electrodes showed a linear range between 1.25 x 10(-4) and 2.48 x 10(-3)M, the epoxy-graphite composite electrodes based on polysulfone composite films allowed the detection of lactate at a linear range of lower concentrations from 1 x 10(-6) to 1.2 x 10(-5)M. Finally, the performance of the LDH-MB-polysulfone-composite film-based SPE's in a flow system was studied. Short response times were obtained (t<30s). Furthermore, repeatability and reproducibility values were notably improved, especially when working with electrodes covered with a polyamide layer prepared with N-(2-aminoethyl)-piperazine.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17141496     DOI: 10.1016/j.bios.2006.10.034

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Enzyme-coated microelectrodes to monitor lactate production in a nanoliter microfluidic cell culture device.

Authors:  Igor A Ges; Franz Baudenbacher
Journal:  Biosens Bioelectron       Date:  2010-06-02       Impact factor: 10.618

Review 2.  Biosensors based on electrochemical lactate detection: A comprehensive review.

Authors:  Kavita Rathee; Vikas Dhull; Rekha Dhull; Sandeep Singh
Journal:  Biochem Biophys Rep       Date:  2015-11-11

Review 3.  Recent Advances in the Fabrication and Application of Screen-Printed Electrochemical (Bio)Sensors Based on Carbon Materials for Biomedical, Agri-Food and Environmental Analyses.

Authors:  Gareth Hughes; Kelly Westmacott; Kevin C Honeychurch; Adrian Crew; Roy M Pemberton; John P Hart
Journal:  Biosensors (Basel)       Date:  2016-09-28

4.  A Dual Electrode Biosensor for Glucose and Lactate Measurement in Normal and Prolonged Obese Mice Using Single Drop of Whole Blood.

Authors:  Mukesh Thapa; Ryong Sung; Yun Seok Heo
Journal:  Biosensors (Basel)       Date:  2021-12-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.