Literature DB >> 17141406

Ultra-trace determination of silver in water samples by electrothermal atomic absorption spectrometry after preconcentration with a ligand-less cloud point extraction methodology.

Jamshid L Manzoori1, Hossein Abdolmohammad-Zadeh, Mohammad Amjadi.   

Abstract

A very simple and ligand-less cloud point extraction (CPE) methodology for the preconcentration of ultra-trace amounts of silver as a prior step to its determination by electrothermal atomic absorption spectrometry (ETAAS) has been developed. The method is based on the extraction of silver at pH 9 by using non-ionic surfactant polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) without adding any chelating agent. Several important variables that affect the CPE efficiency and ETAAS signal were investigated and optimized. The preconcentration of 15 ml sample solution allowed us to achieve an enhancement factor of 60. The calibration graph using the preconcentration system was linear in the range of 5-100 ngl(-1) with a correlation coefficient of 0.9991. The lower limit of detection (3s) obtained in the optimal conditions was 1.2 ngl(-1). The relative standard deviation (R.S.D.) for eight replicate determinations at 30 ngl(-1) Ag level was 4.2%. The proposed method was successfully applied to the ultra-trace determination of silver in water samples.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17141406     DOI: 10.1016/j.jhazmat.2006.10.084

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  6 in total

1.  A reagentless DNA-based electrochemical silver(I) sensor for real time detection of Ag(I) - the effect of probe sequence and orientation on sensor response.

Authors:  Yao Wu; Rebecca Y Lai
Journal:  Biotechnol J       Date:  2016-03-15       Impact factor: 4.677

2.  Adsorptive removal of lanthanum based on hydrothermally synthesized iron oxide-titanium oxide nanoparticles.

Authors:  Ekram Y Danish; Hadi M Marwani; Kholoud F Almoslehi; Esraa M Bakhsh
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-17       Impact factor: 4.223

3.  Oligonucleotide-Based Reusable Electrochemical Silver(I) Sensor and Its Optimization via Probe Packing Density.

Authors:  Kyoungsoo Kim; Je Hyun Bae; Donghoon Han
Journal:  ACS Omega       Date:  2021-04-12

4.  Determination of trace silver in water samples by online column preconcentration flame atomic absorption spectrometry using termite digestion product.

Authors:  Joyce Nunes Bianchin; Edmar Martendal; Eduardo Carasek
Journal:  J Autom Methods Manag Chem       Date:  2011-06-28

5.  Cloud point extraction-flame atomic absorption spectrometry for pre-concentration and determination of trace amounts of silver ions in water samples.

Authors:  Xiupei Yang; Zhihui Jia; Xiaocui Yang; Gu Li; Xiangjun Liao
Journal:  Saudi J Biol Sci       Date:  2017-01-23       Impact factor: 4.219

6.  Dual Functional S-Doped g-C₃N₄ Pinhole Porous Nanosheets for Selective Fluorescence Sensing of Ag⁺ and Visible-Light Photocatalysis of Dyes.

Authors:  Abhijit N Kadam; Md Moniruzzaman; Sang-Wha Lee
Journal:  Molecules       Date:  2019-01-27       Impact factor: 4.411

  6 in total