Near-infrared spectroscopy and imaging for investigating stroke rehabilitation: test-retest reliability and review of the literature.

Gary Strangman1, Richard Goldstein, Scott L Rauch, Joel Stein.   

Abstract

OBJECTIVES: To review the use of near-infrared spectroscopy (NIRS) in stroke rehabilitation and to evaluate NIRS test-retest reliability within-session on a motor control task commonly used in neuroimaging of stroke recovery.
DESIGN: Cohort study.
SETTING: Hospital-based research laboratory. PARTICIPANTS: Nineteen healthy control subjects (age range, 22-55y).
INTERVENTIONS: Subjects performed 2 experimental runs of a finger-opposition task in a block-design paradigm (finger opposition alternated with a fixation rest period) while undergoing multichannel NIRS and physiologic monitoring. MAIN OUTCOME MEASURE: Reliability coefficients (Pearson r) for oxyhemoglobin (O(2)Hb) and deoxyhemoglobin (HHb) correlated amplitude modulations across measurement channels during individual blocks and block averages.
RESULTS: Correlations between single blocks (ie, 16-s slices of data) exhibited a correlation intercept of .33+/-.09 for O(2)Hb. This value was minimally decreased by increasing lag between compared blocks (slope, -.012; P=.019) but was substantially enhanced by averaging across blocks (within-run slope, .11; between-run slope, .044). Correlations using 64 seconds of data reached 0.6. Results for HHb were virtually identical.
CONCLUSIONS: NIRS modulations were repeatable even when comparing very short segments of data. When averaging longer data segments, the test-retest correspondences compared favorably to neuroimaging using other modalities. This suggests that NIRS is a reliable tool for longitudinal stroke rehabilitation and recovery studies.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17140875     DOI: 10.1016/j.apmr.2006.07.269

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  25 in total

1.  Effect of a mirror-like illusion on activation in the precuneus assessed with functional near-infrared spectroscopy.

Authors:  Jan Mehnert; Maddalena Brunetti; Jens Steinbrink; Michael Niedeggen; Christian Dohle
Journal:  J Biomed Opt       Date:  2013-06       Impact factor: 3.170

Review 2.  Functional imaging and related techniques: an introduction for rehabilitation researchers.

Authors:  Bruce Crosson; Anastasia Ford; Keith M McGregor; Marcus Meinzer; Sergey Cheshkov; Xiufeng Li; Delaina Walker-Batson; Richard W Briggs
Journal:  J Rehabil Res Dev       Date:  2010

Review 3.  Review of functional near-infrared spectroscopy in neurorehabilitation.

Authors:  Masahito Mihara; Ichiro Miyai
Journal:  Neurophotonics       Date:  2016-07-12       Impact factor: 3.593

4.  The cortical control of cycling exercise in stroke patients: an fNIRS study.

Authors:  Pei-Yi Lin; Jia-Jin Jason Chen; Sang-I Lin
Journal:  Hum Brain Mapp       Date:  2012-03-28       Impact factor: 5.038

5.  Quantitative assessment of diffuse optical tomography sensitivity to the cerebral cortex using a whole-head probe.

Authors:  Katherine L Perdue; Qianqian Fang; Solomon G Diamond
Journal:  Phys Med Biol       Date:  2012-04-19       Impact factor: 3.609

Review 6.  Optical brain imaging in vivo: techniques and applications from animal to man.

Authors:  Elizabeth M C Hillman
Journal:  J Biomed Opt       Date:  2007 Sep-Oct       Impact factor: 3.170

7.  Non-invasive near infrared fluorescence imaging of CdHgTe quantum dots in mouse model.

Authors:  Haiyan Chen; Yunqing Wang; Jing Xu; Jinzi Ji; Jian Zhang; Yuzhu Hu; Yueqing Gu
Journal:  J Fluoresc       Date:  2008-01-05       Impact factor: 2.217

8.  Multichannel wearable fNIRS-EEG system for long-term clinical monitoring.

Authors:  Ali Kassab; Jérôme Le Lan; Julie Tremblay; Phetsamone Vannasing; Mahya Dehbozorgi; Philippe Pouliot; Anne Gallagher; Frédéric Lesage; Mohamad Sawan; Dang Khoa Nguyen
Journal:  Hum Brain Mapp       Date:  2017-10-23       Impact factor: 5.038

9.  Continuous correction of differential path length factor in near-infrared spectroscopy.

Authors:  Tanveer Talukdar; Jason H Moore; Solomon G Diamond
Journal:  J Biomed Opt       Date:  2013-05       Impact factor: 3.170

10.  Test-retest reliability of functional near infrared spectroscopy in infants.

Authors:  Anna Blasi; Sarah Lloyd-Fox; Mark H Johnson; Clare Elwell
Journal:  Neurophotonics       Date:  2014-09-08       Impact factor: 3.593