Literature DB >> 17140491

Anti-Stokes Raman spectrometry with 1064-nm excitation: an effective instrumental approach for field detection of explosives.

Mary L Lewis1, Ian R Lewis, Peter R Griffiths.   

Abstract

Anti-Stokes Raman spectra of 28 explosive materials were obtained with 1064-nm excitation using fiber-optic sampling and a dispersive spectrograph equipped with a charge-coupled device (CCD) array detector. By using a silicon CCD detector, anti-Stokes features could clearly be observed for the majority of samples from -250 to -1650 cm(-1). Using the fiber-optic probe, spectra were routinely obtained from samples positioned up to twelve meters from the spectrograph within 240 s. The utility of an anti-Stokes correction routine is demonstrated, which routine allowed anti-Stokes spectra measured with 1064-nm excitation to be successfully searched and identified against libraries of Stokes spectra obtained using a Fourier transform (FT) Raman system equipped with a 1064-nm Nd:YAG laser.

Entities:  

Year:  2004        PMID: 17140491     DOI: 10.1366/000370204773580266

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  1 in total

1.  Identification and quantification of explosives in nanolitre solution volumes by Raman spectroscopy in suspended core optical fibers.

Authors:  Georgios Tsiminis; Fenghong Chu; Stephen C Warren-Smith; Nigel A Spooner; Tanya M Monro
Journal:  Sensors (Basel)       Date:  2013-09-30       Impact factor: 3.576

  1 in total