Literature DB >> 17138035

Real-time simultaneous triplane contrast echocardiography gives rapid, accurate, and reproducible assessment of left ventricular volumes and ejection fraction: a comparison with magnetic resonance imaging.

Siri Malm1, Sigmund Frigstad, Einar Sagberg, Per Arvid Steen, Terje Skjarpe.   

Abstract

OBJECTIVE: We sought to compare the feasibility, accuracy, and reproducibility of simultaneous triplane echocardiography for measurements of left ventricular (LV) volumes and ejection fraction (EF) with reference to magnetic resonance imaging (MRI).
METHODS: Digital echocardiography recordings of apical LV views with and without intravenous contrast were collected from 53 consecutive patients with conventional 2-dimensional (2D) imaging and with simultaneous triplane imaging. MRI of multiple LV short-axis sections was performed with a 1.5-T scanner. Endocardial borders were manually traced, and LV volumes and EF from 2D biplane echocardiography and MRI were calculated by method of disks. On triplane data, a triangular mesh was constructed by 3-dimensional interpolation and volumes calculated by the divergence theorem.
RESULTS: Triplane image acquisition was less time-consuming than 2D biplane. Precontrast feasibility was 72% for triplane and 82% for 2D biplane images, increasing to 98% and 100% with contrast, respectively. Bland-Altman analysis demonstrated LV volume underestimation by echocardiography versus MRI, which was significantly reduced by contrast and triplane imaging. The 95% limits of agreement for EF between echocardiography and MRI narrowed using triplane compared with 2D biplane (precontrast -12.5 to 6.7% vs -17.2 to 9.9%, and with contrast -7.1 to 5.8% vs -9.4 to 6.4%, respectively). At intraobserver and interobserver analysis of 20 patients, limits of agreement for EF narrowed with contrast triplane compared with 2D biplane.
CONCLUSION: Simultaneous LV triplane imaging is feasible with simple and rapid image acquisition and volume analysis, and with contrast enhancement it gives accurate and reproducible LV EF measurements compared with MRI.

Entities:  

Mesh:

Year:  2006        PMID: 17138035     DOI: 10.1016/j.echo.2006.06.021

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  9 in total

1.  Three-dimensional echocardiography for left ventricular quantification: fundamental validation and clinical applications.

Authors:  J A van der Heide; S A Kleijn; M F A Aly; J Slikkerveer; O Kamp
Journal:  Neth Heart J       Date:  2011-10       Impact factor: 2.380

2.  The agreement between 3D, standard 2D and triplane 2D speckle tracking: effects of image quality and 3D volume rate.

Authors:  Tudor Trache; Stephan Stöbe; Adrienn Tarr; Dietrich Pfeiffer; Andreas Hagendorff
Journal:  Echo Res Pract       Date:  2014-11-04

3.  Acute contractile recovery extent during biventricular pacing is not associated with follow-up in patients undergoing resynchronization.

Authors:  Federica DeVecchi; Emanuela Facchini; Anna Degiovanni; Chiara Sartori; Chiara Cavallino; Matteo Santagostino; Virginia Di Ruocco; Andrea Magnani; Eraldo Occhetta; Paolo Nicola Marino
Journal:  Int J Cardiol Heart Vasc       Date:  2016-04-01

4.  Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.

Authors:  Jonas Jenner; Peder Sörensson; John Pernow; Kenneth Caidahl; Maria J Eriksson
Journal:  Clin Med Insights Cardiol       Date:  2019-03-05

5.  Echocardiographic assessment of myocardial function and mechanics during veno-venous extracorporeal membrane oxygenation.

Authors:  David G Platts; Kenji Shiino; Jonathan Chan; Darryl J Burstow; Gregory M Scalia; John F Fraser
Journal:  Echo Res Pract       Date:  2019-06-01

Review 6.  Advanced Echocardiography Techniques: The Future Stethoscope of Systemic Diseases.

Authors:  John Iskander; Peter Kelada; Lara Rashad; Doaa Massoud; Peter Afdal; Antoine Fakhry Abdelmassih
Journal:  Curr Probl Cardiol       Date:  2021-03-30       Impact factor: 16.464

7.  Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography.

Authors:  Jøger Hansegård; Stig Urheim; Ketil Lunde; Siri Malm; Stein Inge Rabben
Journal:  Cardiovasc Ultrasound       Date:  2009-04-20       Impact factor: 2.062

8.  Myocardial strain assessed by feature tracking cardiac magnetic resonance in patients with a variety of cardiovascular diseases - A comparison with echocardiography.

Authors:  Kasper Pryds; Anders Hostrup Larsen; Mona Sahlholdt Hansen; Anne Yoon Krogh Grøndal; Rasmus Stilling Tougaard; Nils Henrik Hansson; Tor Skibsted Clemmensen; Brian Bridal Løgstrup; Henrik Wiggers; Won Yong Kim; Hans Erik Bøtker; Roni Ranghøj Nielsen
Journal:  Sci Rep       Date:  2019-08-05       Impact factor: 4.379

Review 9.  Practical guidance for echocardiography for cancer therapeutics-related cardiac dysfunction.

Authors:  Tetsuari Onishi; Yuko Fukuda; Sakiko Miyazaki; Hirotsugu Yamada; Hidekazu Tanaka; Jiro Sakamoto; Masao Daimon; Chisato Izumi; Akiko Nonaka; Satoshi Nakatani; Makoto Akaishi
Journal:  J Echocardiogr       Date:  2020-11-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.