Eliminating cardiac contamination from myoelectric control signals developed by targeted muscle reinnervation.

Ping Zhou1, Todd A Kuiken.   

Abstract

The electrocardiogram (ECG) artifact is a major noise contaminating the myoelectric control signals when using shoulder disarticulation prosthesis. This is an even more significant problem with targeted muscle reinnervation to develop additional myoelectric sites for improved prosthesis control in a bilateral amputee at shoulder disarticulation level. This study aims at removal of ECG artifacts from the myoelectric prosthesis control signals produced from targeted muscle reinnervation. Three ECG artifact removal methods based on template subtracting, wavelet thresholding and adaptive filtering were investigated, respectively. Surface EMG signals were recorded from the reinnervated pectoralis muscles of the amputee. As a key parameter for clinical myoelectric prosthesis control, the amplitude measurement of the signal was used as a performance indicator to evaluate the proposed methods. The feasibility of the different methods for clinical application was also investigated with consideration of the clinical speed requirements and memory limitations of commercial prosthesis controllers.

Mesh:

Year:  2006        PMID: 17135702     DOI: 10.1088/0967-3334/27/12/005

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  7 in total

1.  Control of a six degree of freedom prosthetic arm after targeted muscle reinnervation surgery.

Authors:  Laura A Miller; Robert D Lipschutz; Kathy A Stubblefield; Blair A Lock; He Huang; T Walley Williams; Richard F Weir; Todd A Kuiken
Journal:  Arch Phys Med Rehabil       Date:  2008-11       Impact factor: 3.966

2.  A novel technique for muscle onset detection using surface EMG signals without removal of ECG artifacts.

Authors:  Ping Zhou; Xu Zhang
Journal:  Physiol Meas       Date:  2013-12-17       Impact factor: 2.833

3.  The multiple silicone tube device, "tubes within a tube," for multiplication in nerve reconstruction.

Authors:  Fredrik Johansson; Lars B Dahlin
Journal:  Biomed Res Int       Date:  2014-04-17       Impact factor: 3.411

4.  Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique.

Authors:  S Abbaspour; A Fallah
Journal:  J Biomed Phys Eng       Date:  2014-03-08

5.  Removal of Electrocardiogram Artifacts From Local Field Potentials Recorded by Sensing-Enabled Neurostimulator.

Authors:  Yue Chen; Bozhi Ma; Hongwei Hao; Luming Li
Journal:  Front Neurosci       Date:  2021-04-12       Impact factor: 4.677

6.  FastICA peel-off for ECG interference removal from surface EMG.

Authors:  Maoqi Chen; Xu Zhang; Xiang Chen; Mingxing Zhu; Guanglin Li; Ping Zhou
Journal:  Biomed Eng Online       Date:  2016-06-13       Impact factor: 2.819

Review 7.  Comparative Review of the Algorithms for Removal of Electrocardiographic Interference from Trunk Electromyography.

Authors:  Lin Xu; Elisabetta Peri; Rik Vullings; Chiara Rabotti; Johannes P Van Dijk; Massimo Mischi
Journal:  Sensors (Basel)       Date:  2020-08-29       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.