BACKGROUND: Locked plates (internal fixators) have been found to be an optimal method for the fixation in proximal humeral fractures. In a biomechanical cadaver study the difference between locked and non-locked osteosyntheses was investigated.
METHODS: Paired humeri were harvested, bone density measured. Locked internal fixators were mounted on one specimen; identical plate-screw-systems without locking mechanism applied to the contralateral specimen for comparison. After that, a transverse subcapital osteotomy was performed. With 7 pairs of humeri static tests with increasing axial loads and with 5 pairs dynamic tests with 10 N preload and 80 N maximal axial load for up to 1 million cycles were performed.
RESULTS: In the static experiments the elastic stiffness of the construct was 74% higher in the locked group (median 80 N/mm, quartile range 77-86 N/mm) compared with the non-locked group (46 N/mm, 35.5-56.5 N/mm). The difference was statistically significant (Wilcoxon test for paired samples, P<0.05). Similarly, the linear range until failure was definitely extended in the locked group by 64% (92 N, 89-98 N vs. 56 N, 36.5-73.5 N, P<0.05). Under dynamic loading the non-locked group showed fixation failures between 97,000 and 500,000 cycles. In the locked group no failure was observed until the end of the experiment at 1 million cycles (P<0.0.5). The final deformation was found to be 1 mm (median, quartil range 1.0-1.2 mm) in the non-locked group and 0.3 mm (0.2-0.3 mm) in the locked group (P<0.05). The differences were found equally in lower as well as in higher bone density specimen.
INTERPRETATION: Because of the optimal load transfer between implant and cancellous bone, a locked screw plate interface will reduce fixation failure in proximal humeral fractures.

Entities:  

Mesh:

Year:  2006        PMID: 17134800     DOI: 10.1016/j.clinbiomech.2006.08.009

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  26 in total

1.  Polyaxial Locked Implants in the Treatment of Type Vancouver B1 Periprosthetic Fractures of the Femur: Retrospective Clinical Examination in 58 Cases with Review of the Literature.

Authors:  Jan Meiners; Maximilian Faschingbauer; Christine Voigt; Christian Jürgens; Arndt P Schulz
Journal:  Eur J Trauma Emerg Surg       Date:  2009-07-10       Impact factor: 3.693

Review 2.  [Modern implant design for the osteosynthesis of osteoporotic bone fractures].

Authors:  P Augat; V Bühren
Journal:  Orthopade       Date:  2010-04       Impact factor: 1.087

3.  Biomechanics of four techniques for fixation of the four-part humeral head fracture.

Authors:  Elpídio da Graça; Rodrigo Okubo; Antônio Carlos Shimano; Nilton Mazzer; Cláudio Henrique Barbieri
Journal:  Acta Ortop Bras       Date:  2013-01       Impact factor: 0.513

4.  Locking buttons increase fatigue life of locking plates in a segmental bone defect model.

Authors:  Marc Tompkins; David J Paller; Douglas C Moore; Joseph J Crisco; Richard M Terek
Journal:  Clin Orthop Relat Res       Date:  2012-10-27       Impact factor: 4.176

5.  Biomechanical comparison of gourd-shaped LCP versus LCP for fixation of comminuted tibial shaft fracture.

Authors:  Guo-Hui Xu; Bo Liu; Qi Zhang; Juan Wang; Wei Chen; Yue-Ju Liu; A-Qin Peng; Ying-Ze Zhang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-04-17

Review 6.  [Fractures of the proximal humerus in the elderly : Osteosynthesis versus joint replacement].

Authors:  G Gradl; H-C Pape; M Tingart; D Arbab
Journal:  Orthopade       Date:  2014-04       Impact factor: 1.087

7.  [Biomechanical investigation of fixed-angle plate osteosynthesis of the proximal humerus].

Authors:  G Röderer; M AbouElsoud; F Gebhard; L Claes; A J Aschoff; L Kinzl
Journal:  Unfallchirurg       Date:  2010-02       Impact factor: 1.000

8.  Position of polyaxial versus monoaxial screws in locked plating for proximal humeral fractures: analysis of a prospective randomized study.

Authors:  Ben Ockert; Vera Pedersen; Lucas Geyer; Stefan Wirth; Wolf Mutschler; Stefan Grote
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

9.  Proximal humeral fractures: an understanding of the ideal plate positioning.

Authors:  Pedro José Labronici; Rodrigo Pires e Albuquerque; Vinícius Schott; Robinson Esteves Santos Pires; Willian Dias Belangero; José Sérgio Franco
Journal:  Int Orthop       Date:  2014-07-20       Impact factor: 3.075

10.  Initial results of the s3-humerus plate.

Authors:  J Gille; A P Schulz; Ch Queitsch; A Paech; Ch Jürgens
Journal:  Open Orthop J       Date:  2008-09-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.