Literature DB >> 17133669

[Modern diagnostic assessment of the upper urinary tract using multislice CT urography].

J Kemper1, G Adam, C Nolte-Ernsting.   

Abstract

The advent of Multislice Computed Tomography (MSCT) has made evaluation of the entire urinary tract with high-resolution sections during a single breath-hold a reality. Acquisition of multiple thin overlapping slices provides excellent two-dimensional (2D) and three-dimensional (3D) reformations of the urinary tract. The concept of "Multislice CT Urography (MSCTU)" has emerged from this technical improvement. As a result, a wide range of pathologies inside and outside the urinary tract can be identified. During the last several years, MSCTU has challenged intravenous urography (IVU) in the evaluation of urinary tract abnormalities. Compared with IVU, MSCT(U) is more sensitive and specific in the detection and characterization of a variety of urinary tract disorders, including renal masses and urolithiasis. The main advantage of IVU has been its ability to offer excellent delineation of pelvicalyceal and ureteral anatomy and to depict subtle uroepithelial abnormalities. MSCTU has already shown promising results for overcoming this challenge. Optimal opacification and distension appear to be an essential requirement for a thorough evaluation of the collecting system. Dedicated preparation strategies have been developed to meet these technical difficulties. The biggest disadvantage of MSCTU is the significant radiation exposure. For broad routine clinical application, there is still a need for dose reduction protocols despite the ongoing technical developments in MSCTU. In this article, we outline the different concepts of technical processing for MSCTU and summarize the current role of MSCTU in the evaluation of the upper urinary tract.

Entities:  

Mesh:

Year:  2006        PMID: 17133669     DOI: 10.1055/s-2006-926957

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  2 in total

Review 1.  [Diagnostic imaging--the end of intravenous urography?].

Authors:  W L Strohmaier; R Bartunek
Journal:  Urologe A       Date:  2008-05       Impact factor: 0.639

2.  Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model.

Authors:  Joern Kemper; Marc Regier; Paul M Bansmann; Philipp G C Begemann; Alexander Stork; Hans Dieter Nagel; Gerhard Adam; Claus Nolte-Ernsting
Journal:  Eur Radiol       Date:  2007-02-14       Impact factor: 5.315

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.