Use of PlasmaJet system in patients undergoing abdominal lipectomy following massive weight loss resulting from bariatric surgery: early experience.

Antonio Iannelli1, Abdol Reza Bafghi, Damiano Patrono, Nicolas Sautot-Vial, Jean Gugenheim.   

Abstract

BACKGROUND: Abdominoplasty has become a popular operation among patients seeking body contouring surgery due to the recent development of laparoscopic procedures in bariatric surgery and the epidemic diffusion of obesity. The wide surface of dissection is responsible for common postoperative complications such as seroma and hematoma.
METHODS: PlasmaJet system (PJS), a high energy flow of ionized gas, can be used to stop capillary bleeding from blood and lymph vessels. We tested the PJS in a prospective series of 15 consecutive patients undergoing abdominoplasty after bariatric surgery-induced weight loss.
RESULTS: 14 women underwent abdominoplasty with the PlasmaJet system after a mean weight loss of 48 kg (range 37-53). Mean operative time was 73 min (range 60-87). There was no postoperative complication. Mean fluid output from drains was 351.1 ml/patient (range 60 to 568), and drains were removed at a mean time of 4.8 days (range 3 to 6).
CONCLUSION: These results are in favor of the efficacy of the PJS in reducing the amount of fluid production, and the rate of postoperative complications. However, this should be confirmed in a randomized trial comparing the PJS with standard technique.

Entities:  

Mesh:

Year:  2006        PMID: 17132417     DOI: 10.1381/096089206778869979

Source DB:  PubMed          Journal:  Obes Surg        ISSN: 0960-8923            Impact factor:   4.129


  3 in total

1.  Abdominal lipectomy and mesh repair of midline periumbilical hernia after bariatric surgery: how to spare the umbilicus.

Authors:  Antonio Iannelli; Abdi Bafghi; Chiara Negri; J Gugenheim
Journal:  Obes Surg       Date:  2007-09       Impact factor: 4.129

2.  Use of the PlasmaJet System in patients undergoing abdominal lipectomy following massive weight loss: a randomized controlled trial.

Authors:  Antonio Iannelli; Anne Sophie Schneck; Jean Gugenheim
Journal:  Obes Surg       Date:  2010-01-22       Impact factor: 4.129

3.  Use of neutral argon plasma in the laparoscopic treatment of endometriosis.

Authors:  Ceana Nezhat; Kimberly A Kho; Vadim Morozov
Journal:  JSLS       Date:  2009 Oct-Dec       Impact factor: 2.172

  3 in total