Literature DB >> 1713240

Percutaneous transluminal balloon angioplasty of stenotic standard Blalock-Taussig shunts: effect on choice of initial palliation in cyanotic congenital heart disease.

L A Marks1, A V Mehta, D Marangi.   

Abstract

To date, attempted balloon dilation of stenotic standard Blalock-Taussig shunts has been largely disappointing. It has been suggested that this may be due to the use of balloons of insufficient diameter. Balloon dilation of stenotic Blalock-Taussig shunts was attempted with use of relatively large balloons in five patients (11 to 67 months old) with cyanotic heart disease who were becoming progressively cyanotic and polycythemic (hemoglobin 17.9 +/- 1.1 g/dl) because of discrete shunt stenosis at the site of pulmonary anastomosis. Balloon diameters selected were equal to or within 1 mm of the unobstructed proximal shunt diameter. Before balloon dilation the diameter at the site of the stenosis was 2.8 +/- 0.8 mm (range 1.7 to 4); after balloon dilation it was 5.7 +/- 1.1 mm (range 4.5 to 7.5). The diameter increased in all patients (range 2.0 to 3.5 mm); the mean increase was 2.8 +/- 0.2 mm (p less than 0.005). Expressed as a percent, the increase in diameter at the stenosis ranged from 80% to 182.4% (mean 108.2 +/- 16.8%). Before balloon dilation the systemic oxygen saturation was 72.8 +/- 9.2% (range 55% to 80%) and after balloon dilation it was 83.6 +/- 2.9% (range 80% to 87%). A satisfactory increase (range 6% to 25%) in blood oxygen saturation was seen in all patients; the mean increase was 10.8 +/- 3.2% (p less than 0.01). At follow-up, the oxygen saturation by pulse oximetry was 85.8 +/- 2.9% (mean 5.8 +/- 1.7 months after balloon dilation) and the hemoglobin was 15.6 +/- 1.9 g/dl (mean 6.6 +/- 1.5 months after balloon dilation).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1713240     DOI: 10.1016/0735-1097(91)90613-e

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  2 in total

1.  Catheter-based interventions for modified Blalock-Taussig shunt obstruction: a 20-year experience.

Authors:  Mathilde Bonnet; Jérôme Petit; Virginie Lambert; Philippe Brenot; Jean-Yves Riou; Claude-Yves Angel; Emre Belli; Alban-Elouen Baruteau
Journal:  Pediatr Cardiol       Date:  2015-01-06       Impact factor: 1.655

2.  Transcatheter recanalization of acutely occluded modified systemic to pulmonary artery shunts in infancy.

Authors:  N Sreeram; M Emmel; L Ben-Mime; K Brockmeier; G Bennink
Journal:  Clin Res Cardiol       Date:  2007-11-28       Impact factor: 5.460

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.