Literature DB >> 17130935

Dual-pump coherent anti-Stokes-Raman scattering microscopy.

Ondrej Burkacky1, Andreas Zumbusch, Christian Brackmann, Annika Enejder.   

Abstract

We introduce dual-pump coherent anti-Stokes-Raman scattering (dual-CARS) microscopy. This new technique permits simultaneous imaging of two species characterized by different molecular vibrations, as well as the removal of nonresonant background. This is achieved by using three synchronized laser pulses probing two different vibrations. We demonstrate the virtues of the method by imaging a mixture of nondeuterated and deuterated lipids, clearly distinguishing the individual components and their organization in the mixed arrangement. Further, dual-CARS images of lipid stores in living Caenorhabditis elegans nematodes show that the suppression of the nonresonant background results in significantly enhanced image contrast.

Entities:  

Mesh:

Year:  2006        PMID: 17130935     DOI: 10.1364/ol.31.003656

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  10 in total

Review 1.  Coherent anti-Stokes Raman scattering microscopy.

Authors:  Ji-Xin Cheng
Journal:  Appl Spectrosc       Date:  2007-09       Impact factor: 2.388

2.  Quantitative chemical imaging with background-free multiplex coherent anti-Stokes Raman scattering by dual-soliton Stokes pulses.

Authors:  Kun Chen; Tao Wu; Haoyun Wei; Tian Zhou; Yan Li
Journal:  Biomed Opt Express       Date:  2016-09-09       Impact factor: 3.732

3.  Nonresonant background suppression for coherent anti-Stokes Raman scattering microscopy using a multi-wavelength time-lens source.

Authors:  Bo Li; Kriti Charan; Ke Wang; Tomás Rojo; David Sinefeld; Chris Xu
Journal:  Opt Express       Date:  2016-11-14       Impact factor: 3.894

4.  Biological imaging with coherent Raman scattering microscopy: a tutorial.

Authors:  Alba Alfonso-García; Richa Mittal; Eun Seong Lee; Eric O Potma
Journal:  J Biomed Opt       Date:  2014-07       Impact factor: 3.170

5.  Two-frequency CARS imaging by switching fiber laser excitation.

Authors:  Eric C Rentchler; Ruxin Xie; Rongqing Hui; Carey K Johnson
Journal:  Microsc Res Tech       Date:  2018-01-11       Impact factor: 2.769

6.  Non-Linear Optical Imaging of Obesity-Related Health Risks: Review.

Authors:  Thuc T Le; Ji-Xin Cheng
Journal:  J Innov Opt Health Sci       Date:  2009-01-01

7.  Monitoring of lipid storage in Caenorhabditis elegans using coherent anti-Stokes Raman scattering (CARS) microscopy.

Authors:  Thomas Hellerer; Claes Axäng; Christian Brackmann; Per Hillertz; Marc Pilon; Annika Enejder
Journal:  Proc Natl Acad Sci U S A       Date:  2007-09-05       Impact factor: 11.205

8.  New imaging techniques in the diagnosis of multiple sclerosis.

Authors:  Yan Fu; Thomas M Talavage; Ji-Xin Cheng
Journal:  Expert Opin Med Diagn       Date:  2008-09

9.  Quantitative detection of chemical compounds in human hair with coherent anti-Stokes Raman scattering microscopy.

Authors:  Maxwell Zimmerley; Chia-Yu Lin; David C Oertel; Jennifer M Marsh; Jimmie L Ward; Eric Olaf Potma
Journal:  J Biomed Opt       Date:  2009 Jul-Aug       Impact factor: 3.170

10.  Label-free delineation of brain tumors by coherent anti-Stokes Raman scattering microscopy in an orthotopic mouse model and human glioblastoma.

Authors:  Ortrud Uckermann; Roberta Galli; Sandra Tamosaityte; Elke Leipnitz; Kathrin D Geiger; Gabriele Schackert; Edmund Koch; Gerald Steiner; Matthias Kirsch
Journal:  PLoS One       Date:  2014-09-08       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.