Literature DB >> 17130317

Pneumatic pump reduces leg wound complications in cardiac patients.

Cally K L Ho1, Man Ping Sun, Timmy W K Au, Clement S W Chiu.   

Abstract

Leg wound complications at the site of vein harvest for coronary artery bypass graft, although infrequent, cause significant morbidity. Pneumatic pressure therapy is valuable in venous and lymphatic diseases, but its usefulness after leg vein harvest has not been determined. A prospective randomized controlled trial was conducted on 200 patients, half of whom had sequential pneumatic leg pump therapy postoperatively. Wound healing, extent of lower limb edema, patient satisfaction, and the financial implications of pneumatic pressure therapy were assessed. In the study group, 71 patients had satisfactory wound healing vs. 23 in the control group. The leg wound infection rate in the study group was 3% vs. 15% in the control group ( p = 0.003). Lower limb edema was significantly reduced in the study group in the early postoperative period ( p < 0.05), and the mean postoperative length of hospital stay was reduced by 2.6 days in patients given pneumatic pressure therapy ( p = 0.003). The sequential pneumatic leg pump is an effective, inexpensive, and convenient device that reduces leg wound complications after coronary artery bypass grafting.

Entities:  

Mesh:

Year:  2006        PMID: 17130317     DOI: 10.1177/021849230601400602

Source DB:  PubMed          Journal:  Asian Cardiovasc Thorac Ann        ISSN: 0218-4923


  4 in total

Review 1.  [S1 guideline on intermittent pneumatic compression (IPC)].

Authors:  C Schwahn-Schreiber; F X Breu; E Rabe; I Buschmann; W Döller; G R Lulay; A Miller; E Valesky; S Reich-Schupke
Journal:  Hautarzt       Date:  2018-08       Impact factor: 0.751

2.  Lymphatic pump treatment increases thoracic duct lymph flow in conscious dogs with edema due to constriction of the inferior vena cava.

Authors:  Parna Prajapati; Pankhil Shah; Hollis H King; Arthur G Williams; Pratikkumar Desai; H Fred Downey
Journal:  Lymphat Res Biol       Date:  2010-09       Impact factor: 2.589

3.  Daily use of a muscle pump activator device reduces duration of hospitalization and improves early graft outcomes post-kidney transplantation: A randomized controlled trial.

Authors:  Wen Xie; Max A Levine; Shahid Aquil; Katharine Pacoli; Rafid Al-Ogaili; Patrick P Luke; Alp Sener
Journal:  Can Urol Assoc J       Date:  2021-02       Impact factor: 1.862

4.  CASE REPORT Postoperative Use of the NormaTec Pneumatic Compression Device in Vascular Anomalies.

Authors:  Simon G Talbot; David Kerstein; Laura F Jacobs; Joseph Upton
Journal:  Eplasty       Date:  2012-01-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.