Literature DB >> 17127643

Oxidative stress associated with indoor air pollution and sick building syndrome-related symptoms among office workers in Taiwan.

Chung-Yen Lu1, Yee-Chung Ma, Jia-Min Lin, Chung-Yi Li, Reuy S Lin, Fung-Chang Sung.   

Abstract

This study investigated whether sick building syndrome (SBS) complaints and indoor air pollution for office workers are associated with oxidative stress indicated by urinary 8-hydroxydeoxyguanosine (8-OHdG). With informed consent, 389 employees in 87 government offices of 8 high-rise buildings in Taipei city completed self-reported questionnaires on SBS complaints at work in the past month. Urinary 8-OHdG was determined for each study participant and on-site air pollutants were measured for each office in both indoor and outdoor air. The results showed that urinary 8-OHdG had significant associations with volatile organic compounds and carbon dioxide levels in offices, and with urinary cotinine levels. The mean urinary 8-OHdG level was also significantly higher in participants with SBS symptoms than in those without such complaints (6.16 vs. 5.45 mug/g creatinine, p = .047). The mean 8-OHdG increased as the number of SBS symptoms increased. The multivariate logistic regression analyses showed that the adjusted odds ratios (OR) in relation to micrograms per gram creatinine increase in 8-OHdG were statistically significant for eye dryness (1.12), upper respiratory syndrome (1.17) with particularly nose itching (1.25), sneezing (1.51), dry throat (1.21), skin dryness (1.31), and dizziness (1.19). This study indicates that the 8-OHdG level was significantly associated with SBS complaints after controlling for air pollution and smoking. Whether the 8-OHdG can be used as an effective predictor for SBS symptoms deserves further study.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17127643     DOI: 10.1080/08958370600985859

Source DB:  PubMed          Journal:  Inhal Toxicol        ISSN: 0895-8378            Impact factor:   2.724


  9 in total

1.  Proteome changes in human bronchoalveolar cells following styrene exposure indicate involvement of oxidative stress in the molecular-response mechanism.

Authors:  Nora Mörbt; Iljana Mögel; Stefan Kalkhof; Ralph Feltens; Carmen Röder-Stolinski; Jiang Zheng; Carsten Vogt; Irina Lehmann; Martin von Bergen
Journal:  Proteomics       Date:  2009-11       Impact factor: 3.984

2.  Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds.

Authors:  Chung-Yen Lu; Jia-Min Lin; Ying-Yi Chen; Yi-Chun Chen
Journal:  Int J Environ Res Public Health       Date:  2015-05-27       Impact factor: 3.390

3.  Phytoremediation of benzene, toluene, ethylbenzene and xylene contaminated air by D. deremensis and O. microdasys plants.

Authors:  Mohammad Hossein Mosaddegh; Abbas Jafarian; Adele Ghasemi; Alimohammad Mosaddegh
Journal:  J Environ Health Sci Eng       Date:  2014-01-22

4.  Allostatic load model associated with indoor environmental quality and sick building syndrome among office workers.

Authors:  Chien-Cheng Jung; Hsiu-Hao Liang; Hui-Ling Lee; Nai-Yun Hsu; Huey-Jen Su
Journal:  PLoS One       Date:  2014-04-23       Impact factor: 3.240

5.  Indoor Air Quality in the Metro System in North Taiwan.

Authors:  Ying-Yi Chen; Fung-Chang Sung; Mei-Lien Chen; I-Fang Mao; Chung-Yen Lu
Journal:  Int J Environ Res Public Health       Date:  2016-12-02       Impact factor: 3.390

6.  Personal, Psychosocial and Environmental Factors Related to Sick Building Syndrome in Official Employees of Taiwan.

Authors:  Chung-Yen Lu; Meng-Chuan Tsai; Chih-Hsin Muo; Yu-Hsien Kuo; Fung-Chang Sung; Chin-Ching Wu
Journal:  Int J Environ Res Public Health       Date:  2017-12-22       Impact factor: 3.390

7.  Controlling Indoor Air Pollution from Moxibustion.

Authors:  Chung-Yen Lu; Sy-Yuan Kang; Shu-Hui Liu; Cheng-Wei Mai; Chao-Heng Tseng
Journal:  Int J Environ Res Public Health       Date:  2016-06-20       Impact factor: 3.390

Review 8.  Assessment of Indoor Air Quality Problems in Office-Like Environments: Role of Occupational Health Services.

Authors:  Paolo Carrer; Peder Wolkoff
Journal:  Int J Environ Res Public Health       Date:  2018-04-12       Impact factor: 3.390

9.  Exposure to volatile organic compounds and airway inflammation.

Authors:  Jae-Woo Kwon; Hee-Won Park; Woo Jin Kim; Man-Goo Kim; Seung-Joon Lee
Journal:  Environ Health       Date:  2018-08-07       Impact factor: 5.984

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.