Literature DB >> 17127482

Effects of different blood components on clot retraction analysed by measuring elasticity with a free oscillating rheometer.

Nahreen Tynngård1, Tomas Lindahl, Sofia Ramström, Gösta Berlin.   

Abstract

Free oscillation rheometry (FOR) using the ReoRox 4 instrument makes it possible, at bedside, to study the coagulation process in blood over time and gives information on clotting time and coagulum elastic properties. In order to find out how various factors influence the FOR analysis we studied the coagulation process and change of elasticity over time in non-anticoagulated and citrated blood samples, plasma samples with various platelet concentrations (0-200 x 109/l) and blood samples with various haematocrit (0-40%). Blood samples supplemented with fibrinogen were analysed to elucidate the importance of fibrinogen on elasticity. The importance of the GPIIb/IIIa receptor on platelets was investigated by comparing the elasticity development in blood samples in presence and absence of a GPIIb/IIIa receptor inhibitor, abciximab. Anticoagulation with citrate did not have major influence on the viscoelastic properties of the coagulum. Increasing number of platelets and increasing fibrinogen concentration resulted in higher elasticity while increasing haematocrit gave lower elasticity. Blood samples with GPIIb/IIIa receptor inhibitor had very low elasticity indicating the importance of functional GPIIb/IIIa receptors. In conclusion we consider FOR to be a useful method to study the elastic properties of the coagulum. Various factors such as the number of red blood cells and platelets as well as the fibrinogen concentration should be taken into consideration when evaluating the results. The ReoRox 4 instrument had excellent measuring range and unusually small artefactual effects on clot elasticity induced by the instrument in comparison with published results on other instruments.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17127482     DOI: 10.1080/09537100600759238

Source DB:  PubMed          Journal:  Platelets        ISSN: 0953-7104            Impact factor:   3.862


  9 in total

1.  A Fluid-Structure Interaction Analysis of Blood Clot Motion in a Branch of Pulmonary Arteries.

Authors:  Fateme Mirakhorli; Bahman Vahidi; Marzieh Pazouki; Pouria Talebi Barmi
Journal:  Cardiovasc Eng Technol       Date:  2022-07-05       Impact factor: 2.495

2.  Effect of Thrombus Composition and Viscosity on Sonoreperfusion Efficacy in a Model of Micro-Vascular Obstruction.

Authors:  John J Black; Francois T H Yu; Rick G Schnatz; Xucai Chen; Flordeliza S Villanueva; John J Pacella
Journal:  Ultrasound Med Biol       Date:  2016-05-17       Impact factor: 2.998

3.  Assays of different aspects of haemostasis - what do they measure?

Authors:  Nahreen Tynngård; Tomas L Lindahl; Sofia Ramström
Journal:  Thromb J       Date:  2015-02-05

4.  Comparison of fibrin-based clot elasticity parameters measured by free oscillation rheometry (ReoRox ®) versus thromboelastometry (ROTEM ®).

Authors:  Cristina Solomon; Herbert Schöchl; Marco Ranucci; Ulf Schött; Christoph J Schlimp
Journal:  Scand J Clin Lab Invest       Date:  2015-01-19       Impact factor: 1.713

5.  A constitutive model for developing blood clots with various compositions and their nonlinear viscoelastic behavior.

Authors:  Thomas H S van Kempen; Wouter P Donders; Frans N van de Vosse; Gerrit W M Peters
Journal:  Biomech Model Mechanobiol       Date:  2015-06-05

6.  Free oscillation rheometry monitoring of haemodilution and hypothermia and correction with fibrinogen and factor XIII concentrates.

Authors:  Dag Winstedt; Nahreen Tynngård; Knut Olanders; Ulf Schött
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2013-03-22       Impact factor: 2.953

Review 7.  Biomechanics of haemostasis and thrombosis in health and disease: from the macro- to molecular scale.

Authors:  Reginald Tran; David R Myers; Jordan Ciciliano; Elaissa L Trybus Hardy; Yumiko Sakurai; Byungwook Ahn; Yongzhi Qiu; Robert G Mannino; Meredith E Fay; Wilbur A Lam
Journal:  J Cell Mol Med       Date:  2013-03-14       Impact factor: 5.310

8.  Rotational thromboelastometry and multiple electrode platelet aggregometry in four patients with abnormal routine coagulation studies before removal of epidural catheters after major surgery: a case series and research study.

Authors:  Owain D Thomas; Anna Gustafsson; Ulf Schött
Journal:  J Med Case Rep       Date:  2013-12-30

9.  Thromboelastometry versus free-oscillation rheometry and enoxaparin versus tinzaparin: an in-vitro study comparing two viscoelastic haemostatic tests' dose-responses to two low molecular weight heparins at the time of withdrawing epidural catheters from ten patients after major surgery.

Authors:  Owain Thomas; Anna Larsson; Nahreen Tynngård; Ulf Schött
Journal:  BMC Anesthesiol       Date:  2015-11-24       Impact factor: 2.217