Literature DB >> 17121948

Cephalic vein measurement before forearm fistula creation: does use of a tourniquet to meet the venous diameter threshold increase the number of usable fistulas?

Mark E Lockhart1, Michelle L Robbin, Naomi S Fineberg, Charles G Wells, Michael Allon.   

Abstract

OBJECTIVE: To optimize forearm radiocephalic fistula success, many programs recommend a minimal cephalic vein diameter of 0.25 cm or greater on preoperative sonographic mapping. It is not established, however, whether a vein diameter before or after application of a tourniquet should be used in determining suitability for creation of a forearm fistula.
METHODS: Before forearm radiocephalic fistula placement, preoperative sonographic mapping measured the cephalic vein diameter before and after application of a tourniquet. The patients fell into 2 groups: those with a pretourniquet vein diameter of 0.25 cm or greater (group 1) and those with a pretourniquet vein diameter of less than 0.25 cm that increased to 0.25 cm or greater after application of the tourniquet (group 2). The adequacy of each fistula for dialysis was determined clinically.
RESULTS: Among 73 radiocephalic fistulas with known clinical outcomes, 28 were in group 1, and 45 were in group 2, on the basis of sonography. Fistula success rates were similar in group 1 patients (11 [39%] of 28) and group 2 patients (15 [33%] of 45) (P=.624, Fisher exact test). Inclusion of group 2 patients increased the number of patients recommended for placement of forearm fistulas and increased the total number of usable forearm fistulas from 11 to 26. The overall success rate of forearm fistulas was lower in women (19% versus 50%; P=.015, Fisher exact test).
CONCLUSIONS: The use of a venous tourniquet increases the number of patients eligible for forearm fistulas without decreasing the adequacy rate of these fistulas. Therefore, a tourniquet should routinely be used in patients with small cephalic veins on pretourniquet evaluation.

Entities:  

Mesh:

Year:  2006        PMID: 17121948     DOI: 10.7863/jum.2006.25.12.1541

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  9 in total

Review 1.  Color Doppler ultrasound and arteriovenous fistulas for hemodialysis.

Authors:  Pasquale Zamboli; Fulvio Fiorini; Alessandro D'Amelio; Pasquale Fatuzzo; Antonio Granata
Journal:  J Ultrasound       Date:  2014-07-11

2.  Comparison of radiocephalic fistulas placed in the proximal forearm and in the wrist.

Authors:  Rajeshkumar Bhalodia; Michael Allon; Alan M Hawxby; Ivan D Maya
Journal:  Semin Dial       Date:  2010-08-13       Impact factor: 3.455

3.  Early Predictors of Arteriovenous Fistula Maturation: A Novel Perspective on an Enduring Problem.

Authors:  Crystal A Farrington; Michelle L Robbin; Timmy Lee; Jill Barker-Finkel; Michael Allon
Journal:  J Am Soc Nephrol       Date:  2020-05-18       Impact factor: 10.121

4.  Value of preoperative sonographic vascular evaluation of haemodialysis access in upperlimb.

Authors:  Aishwarya K C; M G Srinath; Sanjay C Desai; Ashok Kumar A; Chandrashekar Ar; Gowtham Gowda A G
Journal:  J Clin Diagn Res       Date:  2014-12-05

Review 5.  Current tools for prediction of arteriovenous fistula outcomes.

Authors:  Damian G McGrogan; Alexander P Maxwell; Aurang Z Khawaja; Nicholas G Inston
Journal:  Clin Kidney J       Date:  2015-04-02

6.  Comparison of distal radiocephalic fistula vs proximal radiocephalic fistula.

Authors:  Biswajit Mishra
Journal:  J Family Med Prim Care       Date:  2021-01-30

7.  Vein diameter after intraoperative dilatation with vessel probes as a predictor of success of hemodialysis arteriovenous fistulas.

Authors:  Branko Fila; Vesna Lovčić; Zdenko Sonicki; Saša Magaš; Zrinka Sudar-Magaš; Marko Malovrh
Journal:  Med Sci Monit       Date:  2014-02-05

8.  Impact of a preoperative evaluation on the outcomes of an arteriovenous fistula.

Authors:  Sung Min Kim; Youngjin Han; Hyunwook Kwon; Hee Sun Hong; Ji Yoon Choi; Hojong Park; Tae-Won Kwon; Yong-Pil Cho
Journal:  Ann Surg Treat Res       Date:  2016-03-30       Impact factor: 1.859

9.  Influence of cephalic vein dilation on arteriovenous fistula maturation in patients with small cephalic veins.

Authors:  Fan Zhang; Yunming Li; Tao Wang; Jie Tao; Jun Zhu; Meng Wei; Liweng Mo; Xianglian Li; Ying Wang; Yue Cheng
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.817

  9 in total