| Literature DB >> 17119780 |
Vanessa Costa Tuma1, Cristina Freitas Ganança, Maurício Malavasi Ganança, Heloisa Helena Caovilla.
Abstract
AIM: To assess whether or not the parameters of fixed and randomized saccadic movements, of pendular tracking and of optokinetic nystagmus in the digital vectonystagmography may show abnormalities in patients with possible diagnosis of peripheral vestibular dysfunction.Entities:
Mesh:
Year: 2006 PMID: 17119780 PMCID: PMC9443596 DOI: 10.1016/s1808-8694(15)30977-0
Source DB: PubMed Journal: Braz J Otorhinolaryngol ISSN: 1808-8686
Comparison of fixed saccadic movement latency, velocity and precision values to the left and to the right.
| Fixed Saccadic Movements | To the left | To the right | ||||
|---|---|---|---|---|---|---|
| Latency | Velocity | Precision | Latency | Velocity | Precision | |
| Average | 203,99 | 144,14 | 104,47 | 198,75 | 144,70 | 103,74 |
| Mean | 195,25 | 142,90 | 104,60 | 191,40 | 146,35 | 103,75 |
| Standard deviation | 57,88 | 19,89 | 9,96 | 56,95 | 23,96 | 8,75 |
| Minimum value | 99,60 | 102,40 | 73,60 | 95,70 | 60,50 | 74,60 |
| Maximum value | 335,90 | 199,90 | 142,60 | 330,00 | 196,30 | 128,30 |
| Lower limit | 189,34 | 139,11 | 101,95 | 184,34 | 138,63 | 101,53 |
| Upper limit | 218,63 | 149,17 | 106,99 | 213,16 | 150,76 | 105,95 |
Comparison of randomized saccadic movement latency, velocity and precision values to the left and to the right.
| Randomized Saccadic Movements | To the left | To the right | ||||
|---|---|---|---|---|---|---|
| Latency | Velocity | Precision | Latency | Velocity | Precision | |
| Average | 206,62 | 96,39 | 100,64 | 197,99 | 84,05 | 102,24 |
| Mean | 200,15 | 95,50 | 102,10 | 192,35 | 83,70 | 101,95 |
| Standard deviation | 53,69 | 20,05 | 13,85 | 40,00 | 13,81 | 15,26 |
| Minimum value | 119,10 | 57,60 | 73,80 | 138,60 | 57,30 | 69,90 |
| Maximum value | 357,40 | 147,10 | 139,30 | 296,80 | 119,80 | 152,50 |
| Lower limit | 193,04 | 91,31 | 97,13 | 187,87 | 80,55 | 98,38 |
| Upper limit | 220,21 | 101,46 | 104,14 | 208,11 | 87,54 | 106,10 |
Comparison of slow component angular velocity (SCV) values and optokinetic nystagmus gain to the left and to the right.
| Optokinetic nystagmus | SCV | SCV | GAIN | PDN | |
|---|---|---|---|---|---|
| p/E | p/D | ||||
| Average | 10,03 | 10,11 | 1,00 | 1,01 | 3,93 |
| Mean | 10,05 | 10,00 | 0,88 | 0,84 | 3,20 |
| Standard deviation | 1,76 | 2,23 | 0,99 | 1,14 | 3,46 |
| Minimum value | 6,10 | 5,50 | 0,59 | 0,53 | 0,00 |
| Maximum value | 13,70 | 20,60 | 8,40 | 9,60 | 13,00 |
| Lower limit | 9,58 | 9,55 | 0,75 | 0,72 | 3,05 |
| Upper limit | 10,48 | 10,67 | 1,25 | 1,30 | 4,80 |
Legend:
SCV = slow component angular velocity
p/D = optokinetic nystagmus to the right
p/E = optokinetic nystagmus to the left
Statistical data on fixed saccadic movement latency, velocity and precision values.
| Fixed Saccadic Movements | Latency | Velocity | Precision |
|---|---|---|---|
| Average | 201,37 | 144,42 | 104,10 |
| Mean | 192,35 | 144,70 | 104,10 |
| Standard deviation | 57,24 | 21,93 | 9,34 |
| Minimum value | 95,70 | 60,50 | 73,60 |
| Maximum value | 335,90 | 199,90 | 142,60 |
| Lower limit | 191,13 | 140,49 | 102,43 |
| Upper limit | 211,61 | 148,34 | 105,77 |
Statistical data on randomized saccadic movement latency, velocity and precision values.
| Randomized Saccadic Movements | Latency | Velocity | Precision |
|---|---|---|---|
| Average | 202,31 | 90,22 | 101,45 |
| Mean | 195,25 | 87,90 | 102,00 |
| Standard deviation | 47,34 | 18,23 | 14,54 |
| Minimum value | 119,10 | 57,30 | 69,90 |
| Maximum value | 357,40 | 147,10 | 152,50 |
| Lower limit | 193,84 | 86,95 | 98,84 |
| Upper limit | 210,78 | 93,48 | 104,05 |
Statistical data on slow component angular velocity and optokinetic nystagmus gain values.
| Optokinetic Nystagmus | SCV | GAIN |
|---|---|---|
| Average | 10,07 | 1,00 |
| Mean | 10,00 | 0,86 |
| Standard deviation | 2,00 | 1,06 |
| Minimum value | 5,50 | 0,53 |
| Maximum value | 20,60 | 9,60 |
| Lower limit | 9,71 | 0,81 |
| Upper limit | 10,43 | 1,19 |
Statistical data on pendular tracking gain values at frequencies of 0.1, 0.2 and 0.4Hz.
| Pendular tracking | GAIN | ||
|---|---|---|---|
| 0,1Hz | 0,2Hz | 0,4Hz | |
| Average | 0,76 | 0,91 | 0,93 |
| Mean | 0,74 | 0,91 | 0,94 |
| Standard deviation | 0,18 | 0,15 | 0,16 |
| Minimum value | 0,33 | 0,60 | 0,54 |
| Maximum value | 1,21 | 1,21 | 1,28 |
| Lower limit | 0,71 | 0,87 | 0,89 |
| Limite Superior | 0,80 | 0,94 | 0,97 |
Distribution of patients with altered and normal fixed saccadic movement latency, velocity and precision.
| Fixed Saccadic Movements | Normal | Altered | p-value | ||
|---|---|---|---|---|---|
| N | % | N | % | ||
| Latency | 0 | 0,0 | 60 | 100,0 | < 0,001* |
| Velocity | 39 | 65,0 | 21 | 35,0 | 0,001* |
| Precision | 60 | 100,0 | 0 | 0,0 | < 0,001* |
Legend
N = number of cases
Distribution of patients with altered and normal randomized saccadic movement latency, velocity and precision.
| Randomized Saccadic Movements | Normal | Altered | p-value | ||
|---|---|---|---|---|---|
| N | % | N | % | ||
| Latency | 0 | 0,0 | 60 | 100,0 | < 0,001* |
| Velocity | 59 | 98,3 | 1 | 1,7 | < 0,001* |
| Precision | 13 | 21,7 | 47 | 78,3 | < 0,001* |
N = number of cases
Distribution of patients with altered and normal slow component angular velocity and optokinetic nystagmus gain.
| Optokinetic nystagmus | Normal | Altered | p-value | ||
|---|---|---|---|---|---|
| N | % | N | % | ||
| SCV | 59 | 98,3 | 1 | 1,7 | < 0,001* |
| Gain | 57 | 95,0 | 3 | 5,0 | < 0,001* |
Legend
SCV = slow component angular velocity
N = number of cases
Distribution of patients with altered and normal pendular tracking gain at frequencies of 0.1, 0.2 and 0.4Hz.
| Pendular tracking | Normal | Altered | p-value | ||
|---|---|---|---|---|---|
| N | % | N | % | ||
| 0,1Hz | 51 | 85,0 | 9 | 15,0 | < 0,001* |
| 0,2Hz | 47 | 78,3 | 13 | 21,7 | < 0,001* |
| 0,4Hz | 52 | 86,7 | 8 | 13,3 | < 0,001* |
Legend
N = number of cases