Literature DB >> 17119735

[Corneal thickness progression from the thinnest point to the limbus: study based on a normal and a keratoconus population to create reference values].

Allan Luz1, Mário Ursulio, Daniel Castañeda, Renato Ambrósio.   

Abstract

PURPOSE: To study the variation and progression of the pachymetric values from the thinnest point towards the limbus in normal and keratoconic corneas; to establish reference curves for this parameter.
METHODS: One hundred eyes with normal corneas and twenty-five eyes with mild keratoconus (stages I and II - Krumeich) were analyzed using the Orbscan. Concentric circles were drawn on the thinnest point of the cornea with increasing radii from 1 to 7 mm. The average results of each circle were calculated and inserted in an Excel table in order to arrange a progression chart for each case starting on the thinnest point. The SPSS software was also used for statistical analysis. Student's t test was then used to compare the found values.
RESULTS: The average values on the thinnest point in normal patients was 511.6 microm (standard deviation 30.6). The average values of the thinnest point in patients with keratoconus was 424.4 microm (standard deviation 56.57). Statistically significant different values were reported (p<0.01) for all circles, and for 6 and 7 mm radii p=0.01.
CONCLUSION: There is a greater pachymetric variability in patients with keratoconus. Keratoconic corneas also have a faster progression of pachymetric values than healthy eyes. Pachymetric progression complements traditional single point evaluation of corneal thickness and must be considered for the screening at refractive candidates. This parameter may represent an indirect index of the biomechanics of corneal tissue but this hypothesis still needs further studies.

Entities:  

Mesh:

Year:  2006        PMID: 17119735     DOI: 10.1590/s0004-27492006000400023

Source DB:  PubMed          Journal:  Arq Bras Oftalmol        ISSN: 0004-2749            Impact factor:   0.872


  2 in total

1.  Epithelial, stromal, and total corneal thickness in keratoconus: three-dimensional display with artemis very-high frequency digital ultrasound.

Authors:  Dan Z Reinstein; Marine Gobbe; Timothy J Archer; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2010-04-07       Impact factor: 3.573

2.  Keratoconus Progression Classification One Year After Performed Crosslinking Method Based on ABCD Keratoconus Grading System.

Authors:  Senad Grisevic; Fanka Gilevska; Alma Biscevic; Melisa Ahmedbegovic-Pjano; Maja Bohac; Ajla Pidro
Journal:  Acta Inform Med       Date:  2020-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.