Literature DB >> 17119417

Evaluation and management of exposed high-density porous polyethylene implants: an experimental study.

Afşin Uysal1, Oğuz Kayiran, Onder Karaaslan, Mustafa Gürhan Ulusoy, Uğur Koçer, Fatma Oz Atalay, Hüseyin Ustün.   

Abstract

Numerous autogenous and alloplastic materials have been used for restoration of contour deformities of the face. Alloplastic materials have come into use to replace autogeneous bone grafts because bone grafts are associated with donor site morbidity, resorption and difficulty in shaping. Porous high-density polyethylene (HDPPE) is a commercial product which is nonallergenic, nonantigenic, noncarcinogenic and nonresorbable, highly stable and somewhat flexible. It has pores of 125-250 mum which enable tissue ingrowth resulting in firm attachment and integration of the implant to the surrounding tissues. In this study we aimed to evaluate the fate of the exposed implants and proposed a method to manage the exposed medpor implants. Twenty rats were used for this experimental study. Three phases involving the implantation, exposition, and the closure of the implants were held respectively. Closure was performed in two groups: 1) After perforating the exposed implants; 2) Without perforating the exposed implants. No serious complications were seen. Perforated exposed implants when covered with flaps rather than grafts could be covered. Exposed implants were not covered easily as indicated by the previous studies. This study demonstrates that early closure of perforated implants with flaps can give the best clinical results when exposed implants are covered in a short period after exposition so that the ingrown fibrous tissues are still intact. We believe that grafting of the exposed medpor implants cannot be effective either in early or late period. Perforating the exposed implants yield successful results as ingrowth of the tissues are enabled.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17119417     DOI: 10.1097/01.scs.0000244913.75102.12

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  5 in total

1.  Crushed Cartilage and Autologous Fat for Dorsal Nasal Refinement.

Authors:  Arvind U Gowda; Navid Pourtaheri; Kitae E Park; Omar Allam; Seija Maniskas; Yassmin Parsaei; Derek M Steinbacher
Journal:  Aesthetic Plast Surg       Date:  2021-04-05       Impact factor: 2.326

2.  Use of HDPE implants in facial skeletal augmentation: Should we rush for it?

Authors:  Ramesh Kumar Sharma
Journal:  Indian J Plast Surg       Date:  2010-01

3.  Use of porous high-density polyethylene grafts in open rhinoplasty: no infectious complication seen in spreader and dorsal grafts.

Authors:  Shabahang Mohammadi; Mohammad Mohseni; Masoumeh Eslami; Hessein Arabzadeh; Morteza Eslami
Journal:  Head Face Med       Date:  2014-12-22       Impact factor: 2.151

4.  In vivo tissue response and durability of five novel synthetic polymers in a rabbit model.

Authors:  E Sahin; C Cingi; G Eskiizmir; N Altintoprak; A Calli; C Calli; I Yilgör; E Yilgör
Journal:  Acta Otorhinolaryngol Ital       Date:  2016-04-29       Impact factor: 2.124

5.  Argon plasma improves the tissue integration and angiogenesis of subcutaneous implants by modifying surface chemistry and topography.

Authors:  Michelle Griffin; Robert Palgrave; Víctor G Baldovino-Medrano; Peter E Butler; Deepak M Kalaskar
Journal:  Int J Nanomedicine       Date:  2018-10-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.