Literature DB >> 17118439

Mechanical and physical properties of carbon-graphite fiber-reinforced polymers intended for implant suprastructures.

Susanna Segerström1, I Eystein Ruyter.   

Abstract

OBJECTIVES: Mechanical properties and quality of fiber/matrix adhesion of poly(methyl methacrylate) (PMMA)-based materials, reinforced with carbon-graphite (CG) fibers that are able to remain in a plastic state until polymerization, were examined.
METHODS: Tubes of cleaned braided CG fibers were treated with a sizing resin. Two resin mixtures, resin A and resin B, stable in the fluid state and containing different cross-linking agents, were reinforced with CG fiber loadings of 24, 36, and 47 wt% (20, 29, and 38 vol.%). In addition, resin B was reinforced with 58 wt% (47 vol.%). After heat-polymerization, flexural strength and modulus were evaluated, both dry and after water storage. Coefficient of thermal expansion, longitudinally and in the transverse direction of the specimens, was determined. Adhesion between fibers and matrix was evaluated with scanning electron microscopy (SEM).
RESULTS: Flexural properties and linear coefficient of thermal expansion were similar for both fiber composites. With increased fiber loading, flexural properties increased. For 47 wt% fibers in polymer A the flexural strength was 547.7 (28.12) MPa and for polymer B 563.3 (89.24) MPa when water saturated. Linear coefficient of thermal expansion was for 47 wt% CG fiber-reinforced polymers; -2.5 x 10(-6) degrees C-1 longitudinally and 62.4 x 10(-6) degrees C-1 in the transverse direction of the specimens. SEM revealed good adhesion between fibers and matrix. More porosity was observed with fiber loading of 58 wt%.
CONCLUSIONS: The fiber treatment and the developed resin matrices resulted in good adhesion between CG fibers and matrix. The properties observed indicate a potential for implant-retained prostheses.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17118439     DOI: 10.1016/j.dental.2006.06.050

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  2 in total

1.  The effect of glass and polyethylene fiber reinforcement on flexural strength of provisional restorative resins: an in vitro study.

Authors:  Parthasarathy Natarajan; C Thulasingam
Journal:  J Indian Prosthodont Soc       Date:  2012-07-14

2.  Analysis of bond strength between a nylon reinforcement structure and dental resins.

Authors:  Leonardo-Jiro-Nomura Nakano; Guilherme-da Rocha-Scalzer Lopes; Aline-Silva Firmino; Jefferson-David-Melo de Matos; Rubens-Nisie Tango; Tarcisio-José-de Arruda Paes-Junior
Journal:  J Clin Exp Dent       Date:  2021-05-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.