Literature DB >> 17117768

Trial fitting of a removable partial denture framework made using computer-aided design and rapid prototyping techniques.

R J Bibb1, D Eggbeer, R J Williams, A Woodward.   

Abstract

Previous studies of CAD/CAM-produced sacrificial patterns for removable partial denture frameworks have been documented but to date, no such restorations have been test-fitted to a patient. This paper provides details of the first trial fitting to a patient of an RPD framework, the sacrificial pattern of which was produced by CAD/CAM and RP technologies. A cast of the patient was scanned and the normal procedures of dental surveying and pattern build were undertaken with reference to the scanned model using computer-aided design. A sacrificial pattern of the design was produced by rapid prototyping technology. After spruing the pattern, investment-casting and finishing techniques were carried out according to conventional principles. The framework was successfully trial-fitted to the patient and clinically judged to be acceptable for the next stage of denture fabrication, that of adding acrylic bases and artificial teeth.

Entities:  

Mesh:

Year:  2006        PMID: 17117768     DOI: 10.1243/09544119JEIM62

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  7 in total

Review 1.  A Scoping Review on the Accuracy of Fit of Removable Partial Dentures in a Developing Digital Context.

Authors:  Noor Al Mortadi; Karem H Alzoubi; Robert Williams
Journal:  Clin Cosmet Investig Dent       Date:  2020-11-19

2.  Evaluation of the flexural strength and microhardness of provisional crown and bridge materials fabricated by different methods.

Authors:  Shruti Digholkar; V N V Madhav; Jayant Palaskar
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

Review 3.  Computer-Based Technologies in Dentistry: Types and Applications.

Authors:  Raja'a M Albuha Al-Mussawi; Farzaneh Farid
Journal:  J Dent (Tehran)       Date:  2016-06

4.  Fit Accuracy of Removable Partial Denture Frameworks Fabricated with CAD/CAM, Rapid Prototyping, and Conventional Techniques: A Systematic Review.

Authors:  Naseer Ahmed; Maria Shakoor Abbasi; Sara Haider; Nimra Ahmed; Syed Rashid Habib; Sara Altamash; Muhammad Sohail Zafar; Mohammad Khursheed Alam
Journal:  Biomed Res Int       Date:  2021-09-06       Impact factor: 3.411

Review 5.  Additive Manufactured Polymers in Dentistry, Current State-of-the-Art and Future Perspectives-A Review.

Authors:  Codruta Victoria Tigmeanu; Lavinia Cosmina Ardelean; Laura-Cristina Rusu; Meda-Lavinia Negrutiu
Journal:  Polymers (Basel)       Date:  2022-09-03       Impact factor: 4.967

Review 6.  A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication.

Authors:  Mehmet Selim Bilgin; Ebru Nur Baytaroğlu; Ali Erdem; Erhan Dilber
Journal:  Eur J Dent       Date:  2016 Apr-Jun

Review 7.  Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology.

Authors:  Khalid A O Arafa
Journal:  Saudi Med J       Date:  2018-01       Impact factor: 1.484

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.