Literature DB >> 17117748

Can measurement of the intima-media thickness of the carotid artery improve the diagnostic value of exercise stress tests?

Hilde Heuten1, Marc Claeys, Inge Goovaerts, Guy Ennekens, Johan Bosmans, Christiaan Vrints.   

Abstract

OBJECTIVE: The diagnostic value of the exercise electrocardiogram (ECG) for the detection of coronary artery disease is hampered by a high proportion of equivocal results, especially in asymptomatic patients. The intima-media thickness of the carotid artery correlates well with the degree of atherosclerosis, also in other vascular beds, such as the coronary arteries. The aim of this study is to evaluate whether measurements of intima-media thickness can improve the diagnostic value of stress ECG in the detection of coronary artery disease.
METHODS: Patients without a history of vascular disease and with equivocal exercise stress ECG results were included. The intima-media thickness was measured with high resolution echography at the posterior wall of the common carotid artery, using an automated edge-tracking method. The diagnosis of coronary artery disease was based on the presence of reversible perfusion defects on exercise MIBI-scintigrams.
RESULTS: A total of 90 patients (46 men, 44 women) with a mean age of 53.7 years were included. The MIBI-scintigraphy was positive in 17. There was no difference in mean intima-media thickness between MIBI positive and MIBI negative patients (635.76 +/- 84.56 microm and 643.89 +/- 107.06 microm, respectively, p = 0.8). Using multiple regression analysis, neither intima-media thickness measurements, nor classic risk factors could predict the result of MIBI-scintigraphy. Intima-media thickness was mainly influenced by age and hypertension.
CONCLUSIONS: In this study, neither intima-media thickness measurements, nor classic risk factors could improve the diagnostic value of stress ECG in the detection of coronary artery disease. In case of equivocal stress results, additional cardiovascular imaging techniques remain recommended.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17117748     DOI: 10.2143/AC.61.5.2017763

Source DB:  PubMed          Journal:  Acta Cardiol        ISSN: 0001-5385            Impact factor:   1.718


  1 in total

1.  Usefulness of carotid ultrasonography in the diagnosis of coronary artery disease in patients undergoing exercise echocardiography.

Authors:  Raúl Franco-Gutiérrez; Alberto José Pérez-Pérez; Virginia Franco-Gutiérrez; Ana María Testa-Fernández; Rafael Carlos Vidal-Pérez; Manuel Lorenzo López-Reboiro; Víctor Manuel Puebla-Rojo; Melisa Santás-Álvarez; María Generosa Crespo-Leiro; Carlos González-Juanatey
Journal:  Cardiovasc Ultrasound       Date:  2018-10-09       Impact factor: 2.062

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.