Literature DB >> 17117735

Ozone artifacts and carbonyl measurements using Tenax GR, Tenax TA, Carbopack B, and Carbopack X adsorbents.

Jae Hwan Lee1, Stuart A Batterman, Chunrong Jia, Sergei Chernyak.   

Abstract

Four popular thermally desorbable adsorbents used for air sampling (Tenax TA, Tenax GR, Carbopack B, and Carbopack X) are examined for the potential to form artifacts with ozone (O3) at environmental concentrations. The performance of these adsorbents for the ketone and aldehyde species identified as O3-adsorbent artifacts was also characterized, including recovery, linearity, and method detection limits (MDLs). Using gas chromatography/mass spectrometry, 13 different artifacts were identified and confirmed for both Tenax TA and Tenax GR, 9 for Carbopack B, but none for Carbopack X. Several O3 artifacts not reported previously were identified, including: pentanal, 3-hexanone, 2-hexanone, hexanal, 3-heptanone, and heptanal with Tenax TA; pentanal, 3-hexanone, 2-hexanone, hexanal, and 3-heptanone on Tenax GR; and 1-octene and 1-nonene with Carbopack B. Levels of straight-chain aldehyde artifacts rapidly diminished after a few cycles of adsorbent conditioning/O3 exposure, and concentrations could be predicted using a first-order model. Phenyl-substituted carbonyl artifacts (benzaldehyde and acetophenone) persisted on Tenax TA and GR even after 10 O3 exposure-conditioning cycles. O3 breakthrough through the adsorbent bed was most rapid in adsorbents that yielded the highest levels of artifacts. Overall, artifact composition and concentration are shown to depend on O3 concentration and dose, conditioning method, and adsorbent type and age. Calibrations showed good linearity, and most compounds had reasonable recoveries, for example, 90 +/- 15% for Tenax TA, 97 +/- 23% for Tenax GR, 101 +/- 24% for Carbopack B, and 79 +/- 25% (91 +/- 9% for n-aldehydes) for Carbopack X. Benzeneacetaldehyde recovery was notably poorer (22-63% across the four adsorbents). MDLs for several compounds were relatively high, up to 5 ng. By accounting for both artifact formation and method performance, this work helps to identify which carbonyl compounds can be measured using thermally desorbable adsorbents and which may be prone to bias because of the formation of O3-adsorbent artifacts.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17117735     DOI: 10.1080/10473289.2006.10464560

Source DB:  PubMed          Journal:  J Air Waste Manag Assoc        ISSN: 1096-2247            Impact factor:   2.235


  4 in total

1.  Performance and storage integrity of dried blood spots for PCB, BFR and pesticide measurements.

Authors:  Stuart Batterman; Sergei Chernyak
Journal:  Sci Total Environ       Date:  2014-07-21       Impact factor: 7.963

2.  The effect of ozone fumigation on the biogenic volatile organic compounds (BVOCs) emitted from Brassica napus above- and below-ground.

Authors:  W J F Acton; W Jud; A Ghirardo; G Wohlfahrt; C N Hewitt; J E Taylor; A Hansel
Journal:  PLoS One       Date:  2018-12-10       Impact factor: 3.240

3.  An Optimized Adsorbent Sampling Combined to Thermal Desorption GC-MS Method for Trimethylsilanol in Industrial Environments.

Authors:  Jae Hwan Lee; Chunrong Jia; Yong Doo Kim; Hong Hyun Kim; Tien Thang Pham; Young Seok Choi; Young Un Seo; Ike Woo Lee
Journal:  Int J Anal Chem       Date:  2012-08-23       Impact factor: 1.885

4.  Profiles of Volatile Biomarkers Detect Tuberculosis from Skin.

Authors:  Rotem Vishinkin; Rami Busool; Elias Mansour; Falk Fish; Ali Esmail; Parveen Kumar; Alaa Gharaa; John C Cancilla; Jose S Torrecilla; Girts Skenders; Marcis Leja; Keertan Dheda; Sarman Singh; Hossam Haick
Journal:  Adv Sci (Weinh)       Date:  2021-06-02       Impact factor: 16.806

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.