Progress in the development of the DexAide right ventricular assist device.

Kiyotaka Fukamachi1, Yoshio Ootaki, David J Horvath, Alex L Massiello, Keiji Kamohara, Masatoshi Akiyama, Faruk Cingoz, Chiyo Ootaki, Michael W Kopcak, Raymond Dessoffy, Jenny Liu, Ji-Feng Chen, Qun Zhou, Stephen Benefit, Leonard A R Golding, Sue Alfini, David T Rowe.   

Abstract

The DexAide right ventricular assist device (RVAD) is an implantable centrifugal pump modified from the CorAide left ventricular assist device. As previously published, in vitro performance testing of the DexAide RVAD has met design criteria, and the nominal operating condition of 4 l/min and 20 mm Hg pressure rise was achieved at 2,000 rpm, with a power consumption of 1.9 watts. In vivo studies in 14 calves have demonstrated acceptable hemodynamic characteristics. The calf inflow cannula design is still evolving to minimize depositions on the cannula observed in most experiments. Fitting studies were performed in 5 cadavers and 2 patients to reconfigure the cannulae for use in humans. The design and development of external electronics have been completed for the stand-alone RVAD system, and verification tests are under way in preparation for preclinical tests. Work on the external electronics design for the biventricular assist system is ongoing. In conclusion, the initial in vitro and in vivo studies have demonstrated acceptable hemodynamic characteristics of the DexAide RVAD. The design and development of the external electronic components for the stand-alone RVAD system have been completed. The calf inflow cannula is being redesigned, and chronic in vivo tests are under way.

Entities:  

Mesh:

Year:  2006        PMID: 17117051     DOI: 10.1097/01.mat.0000240700.03478.d0

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  4 in total

1.  The future of adult cardiac assist devices: novel systems and mechanical circulatory support strategies.

Authors:  Carlo R Bartoli; Robert D Dowling
Journal:  Cardiol Clin       Date:  2011-11       Impact factor: 2.213

2.  Development of a Double-Lumen Cannula for a Percutaneous RVAD.

Authors:  Dongfang Wang; Cameron Jones; Cherry Ballard-Croft; Ju Zhao; Guangfeng Zhao; Stephen Topaz; Joseph B Zwischenberger
Journal:  ASAIO J       Date:  2015 Jul-Aug       Impact factor: 2.872

3.  Introduction of fixed-flow mode in the DexAide right ventricular assist device.

Authors:  Diyar Saeed; Alex L Massiello; Shanaz Shalli; Hideyuki Fumoto; Tetsuya Horai; Tomohiro Anzai; Leonard A R Golding; Kiyotaka Fukamachi
Journal:  J Heart Lung Transplant       Date:  2010-01       Impact factor: 10.247

4.  Development of DexAide right ventricular assist device: update II.

Authors:  Kiyotaka Fukamachi; Diyar Saeed; Alex L Massiello; David J Horvath; Hideyuki Fumoto; Tetsuya Horai; Roula Zahr; Shanaz Shalli; Tomohiro Anzai; Raymond Dessoffy; Jacquelyn Catanese; Ji-Feng Chen; Qun Zhou; Stephen Benefit; Sue Alfini; Leonard A R Golding
Journal:  ASAIO J       Date:  2008 Nov-Dec       Impact factor: 2.872

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.