Literature DB >> 17116385

Simultaneous determination of neomycin sulfate and polymyxin B sulfate by capillary electrophoresis with indirect UV detection.

Piyaporn Srisom1, Boonsom Liawruangrath, Saisunee Liawruangrath, Jonathan M Slater, Sunanta Wangkarn.   

Abstract

A simple and rapid capillary electrophoresis method, with indirect UV detection, for the simultaneous determination of neomycin sulfate and polymyxin B sulfate in pharmaceutical formulations was developed. Critical parameters such as pH, buffer composition and concentration, voltage and injection time have been studied to evaluate, how they affect responses, such as resolution and migration times. Separation was performed on a fused silica capillary with 50 microm i.d. and 27 cm total length at an applied voltage of 6 kV with a 15 mM phosphate run buffer (pH 5.0) containing 40 mM N-(4-hydroxy-phenyl)acetamide and 50 mM tetradecylammonium bromide (TTAB). The detection wavelength was set at 280 nm. Quantitative analysis was validated by testing the reproducibility of the method, giving a relative standard deviation less than 0.4 and 2.4% for the repeatability of migration time and corrected peak area, respectively. Accuracy was tested by spiking eye-ear formulations with standards and the recoveries of neomycin sulfate and polymyxin B sulfate were found to be between 97.44-103.18% and 96.85-101.68%, respectively. Linearity of neomycin sulfate and polymyxin B sulfate were obtained in the ranges of 17-682 and 24-608 microg/mL, respectively, with r(2) values above 0.999. The established TLC-densitometric method was applied to evaluate the proposed CE method, and comparable results were obtained by using CE with much shorter analysis time and a small quantity of solvents consumed. The developed method is also the first report on the simultaneous determination of neomycin sulfate and polymyxin B sulfate in pharmaceutical preparations by CE.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17116385     DOI: 10.1016/j.jpba.2006.09.041

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  High performance liquid chromatography-mass spectrometry assay for polymyxin B1 and B2 in human plasma.

Authors:  Tiffany A Thomas; Emily C Broun; Kirsten M Abildskov; Christine J Kubin; Jennifer Horan; Michael T Yin; Serge Cremers
Journal:  Ther Drug Monit       Date:  2012-08       Impact factor: 3.681

2.  Screening and Optimization of the Reaction of Polymyxin B Sulphate with NBD-Cl for the Synchronous Spectrofluorimetric Determination of Polymyxin B Sulphate in Human Plasma.

Authors:  A M El-Kosasy; Omar Abdel-Aziz; N Magdy; N M El Zahar
Journal:  J Fluoresc       Date:  2015-03-14       Impact factor: 2.217

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.