Literature DB >> 17115215

A hybrid algorithm for PET/CT image merger in hybrid scanners.

John A Kennedy1, Ora Israel, Alex Frenkel, Rachel Bar-Shalom, Haim Azhari.   

Abstract

PURPOSE: To improve the PET image quality of a hybrid PET/CT scanner by merging CT borders with PET texture. PET/CT scanners provide both high-resolution CT images showing anatomical details and PET images of low-resolution physiological information about radiopharmaceutical uptake. Standard smoothing of noisy PET images may further impair PET resolution, reducing small lesion detectability.
METHODS: The CT edge data and the PET texture data were merged using a modified form of an algorithm called HCT (hybrid computed tomography). In merged PET/CT images, each PET pixel value was estimated by iteratively applying a corrected 2D Taylor expansion to each of its eight neighbors. The spatial derivative term was used only near anatomical edges provided by the CT. This counts-preserving algorithm was tested on a special resolution phantom and patient data sets obtained by PET/CT acquisitions.
RESULTS: The HCT algorithm provided phantom PET images with sharp borders and improved resolution (< or = 3 mm as compared to > or = 4 mm). HCT increased the signal to background contrast ratios by an average of 61% (40-89%) while maintaining noise reduction similar to the Gaussian filtering standard in PET. In the clinical PET images, HCT allowed for an improved delineation of pulmonary and pelvic lesions and an improved visualization of the brain.
CONCLUSION: A new reconstruction algorithm for merging CT anatomical edge data with functional PET data has been introduced. The algorithm smooths noisy PET images while retaining sharper edges at corresponding anatomical borders, resulting in an improvement in resolution and contrast ratio.

Entities:  

Mesh:

Year:  2006        PMID: 17115215     DOI: 10.1007/s00259-006-0268-2

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  34 in total

1.  Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.

Authors:  Claude Comtat; Paul E Kinahan; Jeffrey A Fessler; Thomas Beyer; David W Townsend; Michel Defrise; Christian Michel
Journal:  Phys Med Biol       Date:  2002-01-07       Impact factor: 3.609

2.  Is quantitation necessary for oncological PET studies? Against.

Authors:  Michael M Graham
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-01       Impact factor: 9.236

3.  Autofocusing based on power-spectra analysis.

Authors:  S Jutamulia; T Asakura; R D Bahuguna; P C De Guzman
Journal:  Appl Opt       Date:  1994-09-10       Impact factor: 1.980

4.  Minimum cross-entropy reconstruction of PET images using prior anatomical information.

Authors:  B A Ardekani; M Braun; B F Hutton; I Kanno; H Iida
Journal:  Phys Med Biol       Date:  1996-11       Impact factor: 3.609

5.  A computational approach to edge detection.

Authors:  J Canny
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1986-06       Impact factor: 6.226

6.  Performance characteristics of a whole-body PET scanner.

Authors:  T R DeGrado; T G Turkington; J J Williams; C W Stearns; J M Hoffman; R E Coleman
Journal:  J Nucl Med       Date:  1994-08       Impact factor: 10.057

7.  Anatomical-based FDG-PET reconstruction for the detection of hypo-metabolic regions in epilepsy.

Authors:  Kristof Baete; Johan Nuyts; Wim Van Paesschen; Paul Suetens; Patrick Dupont
Journal:  IEEE Trans Med Imaging       Date:  2004-04       Impact factor: 10.048

8.  Can FDG PET be used to successfully direct preoperative biopsy of soft tissue tumours?

Authors:  S F Hain; M J O'Doherty; J Bingham; C Chinyama; M A Smith
Journal:  Nucl Med Commun       Date:  2003-11       Impact factor: 1.690

9.  PET/CT using 18F-FDG in suspected lung cancer recurrence: diagnostic value and impact on patient management.

Authors:  Zohar Keidar; Nissim Haim; Luda Guralnik; Mirjana Wollner; Rachel Bar-Shalom; Alon Ben-Nun; Ora Israel
Journal:  J Nucl Med       Date:  2004-10       Impact factor: 10.057

10.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

Authors:  C Burger; G Goerres; S Schoenes; A Buck; A H R Lonn; G K Von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-04-19       Impact factor: 9.236