Literature DB >> 17114850

Comparative analysis of diagnostic accuracy of different brain biopsy procedures.

Deepali Jain1, Mehar Chand Sharma, Chitra Sarkar, Deepak Gupta, Manmohan Singh, A K Mahapatra.   

Abstract

BACKGROUND: Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. AIMS: The present study was carried out to examine the reliability of the diagnoses made on tumor sample obtained via different stereotactic and ultrasound-guided brain biopsy procedures.
MATERIALS AND METHODS: A retrospective analysis was conducted of all brain biopsies (frame-based and frameless stereotactic and ultrasound-guided) performed in a single tertiary care neurosciences center between 1995 and 2005. The overall diagnostic accuracy achieved on histopathology and correlation with type of biopsy technique was evaluated.
RESULTS: A total of 130 cases were included, which consisted of 82 males and 48 females. Age ranged from 4 to 75 years (mean age 39.5 years). Twenty per cent (27 patients) were in the pediatric age group, while 12% (16 patients) were >or= 60-years of age. A definitive histological diagnosis was established in 109 cases (diagnostic yield 80.2%), which encompassed 101 neoplastic and eight nonneoplastic lesions. Frame-based, frameless stereotactic and ultrasound-guided biopsies were done in 95, 15 and 20 patients respectively. Although the numbers of cases were small there was trend for better yield with frameless image-guided stereotactic biopsy and maximum diagnostic yield was obtained i.e, 87% (13/15) in comparison to conventional frame-based CT-guided stereotactic biopsy and ultrasound-guided biopsy.
CONCLUSIONS: Overall, a trend of higher diagnostic yield was seen in cases with frameless image-guided stereotactic biopsy. Thus, this small series confirms that frameless neuronavigator-guided stereotactic procedures represent the lesion sufficiently in order to make histopathologic diagnosis.

Entities:  

Mesh:

Year:  2006        PMID: 17114850     DOI: 10.4103/0028-3886.28113

Source DB:  PubMed          Journal:  Neurol India        ISSN: 0028-3886            Impact factor:   2.117


  3 in total

1.  Evaluation of intraoperative MRI-assisted stereotactic brain tissue biopsy: a single-center experience in China.

Authors:  Chang-Yu Lu; Zong-Sheng Xu; Xun Ye
Journal:  Chin Neurosurg J       Date:  2019-02-15

2.  Intraparenchymal brain lesion biopsy guided by a rigid endoscope and navigation system.

Authors:  Eiichi Ishikawa; Tetsuya Yamamoto; Masahide Matsuda; Hiroyoshi Akutsu; Alexander Zaboronok; Hidehiro Kohzuki; Shunichiro Miki; Shingo Takano; Akira Matsumura
Journal:  Surg Neurol Int       Date:  2015-09-18

3.  The safety and effectiveness of low field intraoperative MRI guidance in frameless stereotactic biopsies of brain tumours-design and interim analysis of a prospective randomized trial.

Authors:  M Czyż; P Tabakow; A Weiser; B E Lechowicz-Głogowska; L W Zub; W Jarmundowicz
Journal:  Neurosurg Rev       Date:  2013-07-03       Impact factor: 3.042

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.