Literature DB >> 17110773

Distributions of positron-emitting nuclei in proton and carbon-ion therapy studied with GEANT4.

Igor Pshenichnov1, Igor Mishustin, Walter Greiner.   

Abstract

Depth distributions of positron-emitting nuclei in PMMA phantoms are calculated within a Monte Carlo model for heavy-ion therapy (MCHIT) based on the GEANT4 toolkit (version 8.0). The calculated total production rates of (11)C, (10)C and (15)O nuclei are compared with experimental data and with corresponding results of the FLUKA and POSGEN codes. The distributions of e(+) annihilation points are obtained by simulating radioactive decay of unstable nuclei and transporting positrons in the surrounding medium. A finite spatial resolution of the positron emission tomography (PET) is taken into account in a simplified way. Depth distributions of beta(+)-activity as seen by a PET scanner are calculated and compared to available data for PMMA phantoms. The obtained beta(+)-activity profiles are in good agreement with PET data for proton and (12)C beams at energies suitable for particle therapy. The MCHIT capability to predict the beta(+)-activity and dose distributions in tissue-like materials of different chemical composition is demonstrated.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17110773     DOI: 10.1088/0031-9155/51/23/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  The microdosimetric extension in TOPAS: development and comparison with published data.

Authors:  Hongyu Zhu; Yizheng Chen; Wonmo Sung; Aimee L McNamara; Linh T Tran; Lucas N Burigo; Anatoly B Rosenfeld; Junli Li; Bruce Faddegon; Jan Schuemann; Harald Paganetti
Journal:  Phys Med Biol       Date:  2019-07-11       Impact factor: 3.609

Review 2.  Compton imaging for medical applications.

Authors:  Hideaki Tashima; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2022-07-22

Review 3.  Proton therapy verification with PET imaging.

Authors:  Xuping Zhu; Georges El Fakhri
Journal:  Theranostics       Date:  2013-09-19       Impact factor: 11.556

Review 4.  Monitoring of Hadrontherapy Treatments by Means of Charged Particle Detection.

Authors:  Silvia Muraro; Giuseppe Battistoni; Francesco Collamati; Erika De Lucia; Riccardo Faccini; Fernando Ferroni; Salvatore Fiore; Paola Frallicciardi; Michela Marafini; Ilaria Mattei; Silvio Morganti; Riccardo Paramatti; Luca Piersanti; Davide Pinci; Antoni Rucinski; Andrea Russomando; Alessio Sarti; Adalberto Sciubba; Elena Solfaroli-Camillocci; Marco Toppi; Giacomo Traini; Cecilia Voena; Vincenzo Patera
Journal:  Front Oncol       Date:  2016-08-03       Impact factor: 6.244

5.  Carbon range verification with 718 keV Compton imaging.

Authors:  Raj Kumar Parajuli; Makoto Sakai; Kazuo Arakawa; Yoshiki Kubota; Nobuteru Kubo; Mutsumi Tashiro
Journal:  Sci Rep       Date:  2021-11-04       Impact factor: 4.379

6.  Basics of particle therapy I: physics.

Authors:  Seo Hyun Park; Jin Oh Kang
Journal:  Radiat Oncol J       Date:  2011-09-30

Review 7.  Range Verification Methods in Particle Therapy: Underlying Physics and Monte Carlo Modeling.

Authors:  Aafke Christine Kraan
Journal:  Front Oncol       Date:  2015-07-07       Impact factor: 6.244

  7 in total