Literature DB >> 17110179

A simple and rapid HPLC/UV method for the simultaneous quantification of theophylline and etofylline in human plasma.

Ramakrishna V S Nirogi1, Vishwottam N Kandikere, Manoj Shukla, Koteshwara Mudigonda, Devender R Ajjala.   

Abstract

A simple, sensitive and selective high performance liquid chromatography (HPLC) method with ultraviolet detection (272 nm) was developed and validated for the simultaneous quantification of theophylline and etofylline in human plasma. Following rapid sample preparation, the analytes and internal standard (hydrochlorothiazide) were separated using an isocratic mobile phase on a reverse phase C18 column. The lower limit of quantification was 100 ng/mL for both theophylline and etofylline with a relative standard deviation of less than 6%. A linear dynamic range of 100-10,000 ng/mL for both theophylline and etofylline was established. This HPLC method was validated with between-batch precision of 2.2-6.0 and 1.4-3.7% for theophylline and etofylline, respectively. The between-batch accuracy was 94.3-98.0 and 95.4-98.2%, respectively. Stability of theophylline and etofylline in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is simple and rugged enough to be used in pharmacokinetic studies.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17110179     DOI: 10.1016/j.jchromb.2006.10.035

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Design, optimization and characterisation of polymeric microneedle arrays prepared by a novel laser-based micromoulding technique.

Authors:  Ryan F Donnelly; Rita Majithiya; Thakur Raghu Raj Singh; Desmond I J Morrow; Martin J Garland; Yusuf K Demir; Katarzyna Migalska; Elizabeth Ryan; David Gillen; Christopher J Scott; A David Woolfson
Journal:  Pharm Res       Date:  2010-05-19       Impact factor: 4.200

2.  A Disposable Sensor Chip Using a Paste Electrode with Surface-Imprinted Graphite Particles for Rapid and Reagentless Monitoring of Theophylline.

Authors:  Tomoji Ohishi; Yasuo Yoshimi
Journal:  Molecules       Date:  2022-04-11       Impact factor: 4.927

3.  Hydrogel-Forming Microneedle Arrays Allow Detection of Drugs and Glucose In Vivo: Potential for Use in Diagnosis and Therapeutic Drug Monitoring.

Authors:  Ester Caffarel-Salvador; Aaron J Brady; Eyman Eltayib; Teng Meng; Ana Alonso-Vicente; Patricia Gonzalez-Vazquez; Barbara M Torrisi; Eva Maria Vicente-Perez; Karen Mooney; David S Jones; Steven E J Bell; Colin P McCoy; Helen O McCarthy; James C McElnay; Ryan F Donnelly
Journal:  PLoS One       Date:  2015-12-30       Impact factor: 3.240

4.  Quantification of theophylline or paracetamol in milk matrices by high-performance liquid chromatography.

Authors:  Tânia A P Fernandes; João P Aguiar; Ana I Fernandes; João F Pinto
Journal:  J Pharm Anal       Date:  2017-07-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.