Literature DB >> 17106883

The balance between endotoxin accumulation and clearance during particle-induced osteolysis in murine calvaria.

Joscelyn M Tatro1, Naoya Taki, Andrew S Islam, Victor M Goldberg, Clare M Rimnac, Claire M Doerschuk, Matthew C Stewart, Edward M Greenfield.   

Abstract

Bacterial endotoxin may contribute to aseptic loosening of orthopedic implants even in the absence of clinical or microbiological evidence of infection. One potential source of endotoxin during aseptic loosening is systemically circulating endotoxin, derived from intestinal flora, minor infections, or dental procedures, that may bind to wear particles. The current study demonstrates that systemically derived endotoxin accumulates when 'endotoxin-free' titanium and polyethylene particles are implanted on murine calvaria. Time-course experiments and experiments using germ-free mice rule out the possibility that the observed endotoxin accumulation may be due to bacterial contamination. In contrast, endotoxin is cleared from titanium particles that originally carry high amounts of adherent endotoxin. The mechanism of endotoxin clearance is not dependent on induction of a respiratory burst. Taken together, these results indicate that a balance between endotoxin accumulation and endotoxin clearance controls the steady-state level of endotoxin surrounding orthopedic wear particles implanted on murine calvaria. This balance may regulate the rate of osteolysis in the murine calvaria model as well as in patients with aseptic loosening. (c) 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17106883     DOI: 10.1002/jor.20289

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  21 in total

1.  Bacterial pathogen-associated molecular patterns stimulate biological activity of orthopaedic wear particles by activating cognate Toll-like receptors.

Authors:  Edward M Greenfield; Michelle A Beidelschies; Joscelyn M Tatro; Victor M Goldberg; Amy G Hise
Journal:  J Biol Chem       Date:  2010-08-19       Impact factor: 5.157

2.  Bone turnover markers correlate with implant fixation in a rat model using LPS-doped particles to induced implant loosening.

Authors:  Shuo Liu; Amarjit S Virdi; Kotaro Sena; W Frank Hughes; Dale R Sumner
Journal:  J Biomed Mater Res A       Date:  2012-01-24       Impact factor: 4.396

Review 3.  Do genetic susceptibility, Toll-like receptors, and pathogen-associated molecular patterns modulate the effects of wear?

Authors:  Edward M Greenfield
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

4.  Innate immunity sensors participating in pathophysiology of joint diseases: a brief overview.

Authors:  Jiri Gallo; Milan Raska; Yrjo T Konttinen; Christophe Nich; Stuart B Goodman
Journal:  J Long Term Eff Med Implants       Date:  2014

5.  Innate immune reactions in septic and aseptic osteolysis around hip implants.

Authors:  Jukka Pajarinen; Eemeli Jamsen; Yrjo T Konttinen; Stuart B Goodman
Journal:  J Long Term Eff Med Implants       Date:  2014

6.  Macrophage integrins modulate response to ultra-high molecular weight polyethylene particles and direct particle-induced osteolysis.

Authors:  Toral D Zaveri; Natalia V Dolgova; Jamal S Lewis; Kiri Hamaker; Michael J Clare-Salzler; Benjamin G Keselowsky
Journal:  Biomaterials       Date:  2016-10-27       Impact factor: 12.479

Review 7.  Chronic inflammation in biomaterial-induced periprosthetic osteolysis: NF-κB as a therapeutic target.

Authors:  Tzu-hua Lin; Yasunobu Tamaki; Jukka Pajarinen; Heather A Waters; Deanna K Woo; Zhenyu Yao; Stuart B Goodman
Journal:  Acta Biomater       Date:  2013-10-01       Impact factor: 8.947

8.  Integrin-directed modulation of macrophage responses to biomaterials.

Authors:  Toral D Zaveri; Jamal S Lewis; Natalia V Dolgova; Michael J Clare-Salzler; Benjamin G Keselowsky
Journal:  Biomaterials       Date:  2014-01-24       Impact factor: 12.479

9.  Presence of interleukin-17C in the tissue around aseptic loosened implants.

Authors:  Changhe Hou; Yangchun Zhang; Shiming Yu; Ziqing Li; Qiyi Zhai; Zhanchun Li; Xibao Zhang; Jianhong Xiao; Puyi Sheng
Journal:  Int Orthop       Date:  2013-03-10       Impact factor: 3.075

10.  Direct subcutaneous injection of polyethylene particles over the murine calvaria results in dramatic osteolysis.

Authors:  Allison J Rao; Stefan Zwingenberger; Roberto Valladares; Chenguang Li; Robert Lane Smith; Stuart B Goodman; Christophe Nich
Journal:  Int Orthop       Date:  2013-04-21       Impact factor: 3.075

View more